Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150
or 120mm, the choice of which is left to the installer.
Install the dumper 10
Fix the pipe in position using adequate pipe clamps
(not supplied).
To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the dumper 10.
Remove any activated charcoal filters.
ø 120
ø 150
10
10
9
RECIRCULATION VERSION AIR OUTLET
Cut a hole ø 125 mm in any shelf that may be posi-
tioned over the hood.
Insert the reducer flange 9 on the hood body outlet.
Connect the flange to the outlet on the shelf over the
hood by using a flexible or rigid pipe ø120 mm.
Fix the pipe in position using sufficient pipe clamps
(not supplied).
Fix the air outlet grid 8 on the recirculation air outlet
by using the 2 screws 12e (2,9 x 9,5) provided.
Ensure that the activated charcoal filters have been
inserted.
9
ø 125
8
12e
ELECTRICAL CONNECTION
Connect the hood to the mains through a two-
p
ole switch having a contact gap of at least 3
mm..