Tefal PT3040F0 Pure Air Nanocaptur

User Manual - Page 6

For PT3040F0.

PDF File Manual, 44 pages, Download pdf file

Loading ...
Loading ...
Loading ...
6
Frequency of cleaning/replacing the lters :
Filter Clean/replace Frequency Filter codes
Pre filter Clean Every 2 months
2in1 Active Carbon & Allergy+ Filter Replace Every 12 months XD6230
NanoCaptur+ filter (only PT3040 model) Replace
Color changing (see
color chart on filter)
or every 12 months in
case of no saturation.
XD6082
These figures are based on tests in which the air purifier is used for 8 hours per day in quiet mode.
You may need to replace the filters more often depending on the air quality and how often the air purifier
is used. The filter replacement indicator (7) will turn on when the filters need to be replaced. To replace the
filters, please refer to the section “Disassembling / Reassembling filters”.
Important! When the filter replacement indicator turns on, check whether the filters need to be replaced.
When the lter replacement indicator (7) turns on, this indicates that the 2in1 Active Carbon & Allergy+
lter needs to be replaced.
The pre-lter can be cleaned with a vacuum cleaner or rinsed in water.
Important: Resetting the filter
After replacing the filter, press the brightness button (4) for 3 seconds to reset the filter settings.
Performing a force reset:
If you replace a filter before the end of its lifespan, press the brightness button (4) for 3 seconds to reset the
filter settings.
Caution :
If the granules become "white opaque", filter needs to be removed from the purifier until the granules
become transparent again.
If the opaque aspect persists, filter need to be changed.
If the granule become "crumbly", filter need to be changed.
The appliance efficiency can be reduced if the pre-filter is not cleaned regularly.
Never use a pre-filter that is still damp.
The pre-filter is the only filter which can be re-used and washed with water. The 2in1 Active Carbon & Allergy+
filter cannot be cleaned and re-used. Never wash with water. The 2in1 Active Carbon & Allergy+ filter must be
replaced after the end of its lifespan. For optimum performance of the appliance, only use filters provided by
Tefal. If the Nanocaptur+ filter granules become opaque white or/and crumbly, the filter needs to be changed.
Please note: certain filters may emit a temporary slight odour, due to the transport and storage conditions.
« TIPS FOR CHANGING FILTERS »
Avoid handling used lters if you suer from allergies or asthma.
Wear gloves when changing the lters, or wash your hands well afterwards.
Put used lters directly into a closed, air-tight bag before throwing them away to avoid
spreading pollutants.
Pollution sensors
The particle sensor need to be cleaned regularly (every 2 months) and appropriately.
Make sure you turn off and unplug the appliance before cleaning the pollution sensors and follow the
recommendations below:
1. Clean the air inlet and outlet using a soft brush or cloth.
2. Open the sensor cover located on the left hand side of the appliance.
3. Lightly wet a cotton swab and remove any dust from the lens and the inlet/outlet. Wipe using a dry cotton swab.
4. Clean the sensor using a soft brush or vacuum cleaner.
Loading ...
Loading ...
Loading ...