5
Allow only quali ed licensed LP gas dealers to properly  ll or repair your LP gas cylinder.
New tanks should be purged prior to  lling; inform LP gas dealer if you are using a new tank.
DO NOT allow the cylinder to be  lled beyond 80% capacity. Over- lled tanks can create a
dangerous condition. Over- lled tanks can build-up pressure and cause the relief valve to expel
propane gas vapors. The vapor is combustible and if it comes in contact with a spark source or
ame an explosion causing severe burns, bodily harm, or death could occur.
• Always use a protective cylinder cap when grill is not connected to cylinder.
If you exchange a cylinder with a quali ed exchange program, the new cylinder must have
a Type 1 valve and an over- lling prevention device (OPD).
Inspect the propane tank valve rubber seal for cracks, wear or deterioration prior to use. A
damaged rubber seal can cause a gas leak, possibly resulting in an explosion, re or severe
bodily harm.
FILLING THE LP GAS CYLINDER (TANK):
WARNING
LP GAS CYLINDER (TANK) SPECIFICATIONS:
LP gas cylinder (not supplied with this grill)
The LP (Liquid Propane) gas cylinder speci cally designed to be used with this grill must be 12” (30.5 cm)
diameter x 18” (45.7 cm) tall and have a 20 lb. (9.1 kg) capacity incorporating a Type 1 cylinder valve and
an over- lling protection device (OPD).
This grill is designed to  t Worthington, Manchester or SMPC brand 20 lb. (9.1 kg) cylinders. Other brand
DOT cylinders may  t this grill if the cylinder has similar dimensions of the top and bottom rings.
The installation of this appliance must be in accordance with:
All applicable local codes, or in the absence of local codes, either:
National Fuel Gas Code ANSI Z223.1 NFPA 54
Natural Gas and Propane Installation Code: CAN/CGA B149.1
Natural Gas Installation Code: CAN/CGA B149.1 (Canada)
Propane Installation Code: CAN/CGA B149.2 (Canada)
To check your local codes, see your local LP gas dealer or natural gas company. This grill was not
intended to be connected to a natural gas supply line.
When purchasing or exchanging a cylinder for your gas grill, it must be constructed and marked in
accordance with the speci cations for LP gas cylinders of the U.S. Department of Transportation (DOT)
or the National Standard of Canada, CAN/CSA-B339 Cylinders, Spheres and Tubes for Transportation of
Dangerous Goods; and Commission, as applicable; and provided with a listed over- lling prevention device
(OPD), and provided with a cylinder connection device compatible with the connection for outdoor cooking
appliances.
The cylinder must also be equipped with:
A shut-off valve terminating in a Type 1 gas cylinder valve outlet.
A Type 1 valve that prevents gas  ow until a positive seal is obtained.
An arrangement for vapor withdrawal.
A collar to protect the cylinder shut-off valve.
A safety relief device having direct communication with the vapor space of the cylinder.
A listed over- lling prevention device (OPD).