Installation Instructions (cont’d)
11
3. Remove the insulation block and pad.
5. Remove the screws from terminal 2 of the element, and
move the looped end of the wire aside.
6. The buss bar is labeled 5500 W. Place the buss bar over ter-
minals 2 and 3 with the 5500 W visible. Install the extra
screw provided into terminal 3.
7. The wire removed from terminal 2 has a looped end. It must
remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.
5500 W
4. Lower Element: Lift out the tab as shown to unclip the ter-
minal cover from the thermostat. The terminal cover can
now be removed from the thermostat.
THERMOSTAT
BRACKET
PLASTIC TABS ON
BOTH SIDES OF
TERMINAL COVER
HOLD IT IN
PLACE.
TANK
ELEMENT
LOWER THERMOSTAT
JACKET
JACKET
Lift out tab to unclip
terminal cover from
thermostat.
TERMINAL COVER
CLIPPED TO THER-
MOSTAT AT THIS
POINT
2. The convertible element is located behind the lower access
panel of the water heater. Remove the two screws securing
the access panel, and remove panel.
8. Tighten terminals 2 and 3 to ensure proper electrical
connection.
WARNING
Failure to tighten terminal screws can cause a fire which
can result in DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.