Loading ...
Loading ...
Loading ...
8
INSTALLATION
FIG. 4
TECHNICAL INFORMATION
FOR THE INSTALLER
This appliance shall be installed only by authorised
personnel and in accordance with the
manufacturer’s installation instructions, local gas
fitting regulations, municipal codes, electrical wiring
regulations, AS/NZS 5601- Gas Installation and any
other statutory regulations. Ventilation must be in
accordance with AS/NZS 5601 - Gas installation. In
general, the appliance should have adequate
ventilation for complete combustion of gas,
proper flueing and to maintain temperature of
immediate surroundings safe limits.
The wall and bench surfaces must be capable of
sustaining temperatures of 75 °C. All laminates,
fixing adhesive and surfacing materials should
be certified suitable for this temperature.
3) INSTALLING THE HOTPLATE
Check that the appliance is in a good condition after
having removed the outer packaging and internal
wrappings from around the various loose parts. In
case of doubt, do not use the appliance and contact
qualified personnel.
Never leave the packaging materials (cardboard,
bags, polystyrene foam, nails, etc.) within
childrens reach since they could become
potential sources of danger.
The measurements of the opening made in the top of
the modular cabinet and into which the hotplate will be
installed are indicated in either fig. 4. Always comply
with the measurements given for the hole into which
the appliance will be recessed (see fig. 4-4/a)
.
The appliance belongs to class 3 and is
therefore subject to all the provisions
established by the provisions governing such
appliances.
Any adjoining wall surface situated within 200 mm from
the edge of any hob burner must be a suitable non-
combustible material for a height of 150 mm for the entire
length of the hob. Any combustible construction above
the hotplate must be at least 650 mm above the top of
the burner and no construction shall be within 450 mm
above the top of the burner. A minimum depth of 70 mm
from the top of the worktop surface must be provided for
the appliance.
CAUTION:
the installer shall test the appliance
before leaving. Test the safety
operation of the ignition system on all
burners individually and combined.