PUT YOUR DISPENSING
1, Fasten the solution pump to the base with 4 nylon
screws and nuts, as shown
2. Working through the tank fill hole, assemble the
Low Level Indicator to the tank as shown, Positon the
upper window port so the red indicator is easily seen_
3. Set the reservoir (tank) into the round indent in
the base
4. Cut a 14" length of tubing and connect to the
suction (bottom) bulkhead fitting on the tank, Use a
sharp knife to cut square. Connect the tubing to the
SUCTION VALVE on the solution pump as follow&
NOTE: BE SURE TO CONNECT TO THE SUCTION
VALVE IF CONNECTED TO THE WRONG VALVE,
THE SYSTEM WILL NOT WORK,
- Take the holding nut off the suction valve and slide
over the end of the tubing. Push the tubing onto the
end tip of the valve as far as it will go, Slide the holding
nut up and tighten with your finger&
NOTE: If the tubing is cold, dip the end of it in hot
water to make it easier to work with,
5. From the tubing included, cut off about a 33 in,
length, Be sure both ends are square Then connect
this tubing between the solution pump RETURN TO
SUPPLY VALVE and the RETURN bulkhead fitting
on the tank_ Be sure to tighten both holding nuts.
6. Cut a 2 in piece of tubing and, looking at Key No_9
on page !8, connect the strainer to the suction bulk-
head fitting, inside the tank
Parts of
Low Level
Indicator
Reservort
(Tank)
RETURN
Bulkhead Fitting
Solution Pump "_
SUCTION
Fitting
Nylon Screw (4) __
Base
/
Nylon Nut (4)
I
RETURN TO
SUPPLY
VALVE
6