In very humid areas. Moisture or steam can cause nuisance alarms.
In insect-infested areas.
Smoke alarms should not be installed within 3 ft (.9m) of the follow-
ing: the door to a kitchen, the door to a bathroom containing a tub or
shower, forced air supply ducts used for heating or cooling, ceiling or
whole house ventilating fans, or other high air flow areas.
Kitchens. Normal cooking may cause nuisance alarms. If a kitchen
alarm is desired, it should have an alarm silence feature or be a pho-
toelectric type.
Near fluorescent lights. Electronic “noise” may cause nuisance
alarms.
Smoke alarms are not to be used with detector guards unless the
combination (alarm and guard) has been evaluated and found suit-
able for that purpose.
3. INSTALLATION INSTRUCTIONS
WIRING REQUIREMENTS
This smoke alarm should be installed on a U.L. listed or recog-
nized junction box. All connections should be made by a quali-
fied electrician and all wiring used shall be in accordance with
articles 210 and 300.3(B) of the U.S. National Electrical Code
ANSI/NFPA 70, NFPA 72 and/or any other codes having jurisdic-
tion in your area. The multiple station interconnect wiring to
the alarms must be run in the same raceway or cable as the AC
power wiring. In addition, the resistance of the interconnect wir-
ing shall be a maximum of 10 ohms.
The appropriate power source is 120 Volt AC Single Phase sup-
plied from a non-switchable circuit which is not protected by a
ground fault interrupter.
WARNING: This alarm cannot be operated from power derived
from a square wave, modified square wave or modified sine
wave inverter. These types of inverters are sometimes used to
supply power to the structure in off grid installations, such as
solar or wind derived power sources. These power sources pro-
duce high peak voltages that will damage the alarm.
WIRING INSTRUCTIONS FOR AC QUICK CONNECT HARNESS
CAUTION! TURN OFF THE MAIN POWER TO THE CIRCUIT
BEFORE WIRING THE ALARM.
For alarms that are used as single station, DO NOT CONNECT
THE RED WIRE TO ANYTHING. Leave the red wire insulating cap