29INSTALLATION
ENGLISH
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or
restricted.
Error
Code
Possible Cause & Solution
Temp
sensor
error
Temperature sensor failure.
Turn off the appliance and call for
service.
Humidi
ty
sensor
error
Humidity sensor failure.
Turn off the appliance and call for
service.
High
voltage
Low
voltage
Power
supply
/ Power
issue
Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
Reset circuit breaker or replace
fuse. Do not increase the fuse
capacity.
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
If the problem is a circuit overload,
have it corrected by a qualified
electrician.
Gas
supply
Gas supply or service turned off. (Gas
model only.)
Confirm that house gas shutoff and
the dryer gas shutoff are both fully
open.
Excess or crushed
transition duct
Too many elbows or
exhaust too long