For non-vented (recirculating) installations, the blower
position must be changed:
Remove screws and rear support.
Rotate the blower and attach to front mounting plate.
Install the blower mounting screws.
B
A
A
A. Rearsupport
Remove the blower mounting screws. Push up on the
blower to detach the blower from the mounting plate.
Remove the vent knockout from the front mounting plate.
A
6.
A. Blower mounting screws
B. Front mounting plate
Install charcoal filters. See the "Range Hood Care"
section.
Remove the round knockout from the top or back of the
range hood (depending on your wiring location) for the wiring
strain relief and install a 1/2"UL listed or CSA approved strain
relief.
C B
A. Front mounting plate knockout
B. Blower mounting screws
C. Blower
A. Round knockout
7. Using 2 people, lift range hood into final location. Feed
enough electrical wire through the strain relief to make
connections in the terminal box. Tighten the strain relief
screws.
8. Position the range hood so that the large end of the keyhole
slots are over the mounting screws. Then push the hood
toward the wall so that the screws are in the neck of the slots.
The hood should be against the wall. Tighten the mounting
screws, making sure mounting screws are in the narrow neck
of the slots.
9. Check that damper, if used, rotates up and down freely.
11