TROUBLESHOOTING Beforecallingfor service,reviewthislist.Itmaysaveyoutimeandexpense.Thislist
includes common occurences that are not the resu{t of defective workmanship or
GUIDE materials in this appl{ance.
PROBLEM CAUSE I CORRECTION
FREEZER DOES NOT RUN
FPaezer does not run. Freezer isplugged into a circuit * Use another circuit. _fyou are unsure about the oulJet,
that has a ground fault interrupt, have it checked by a certified technician.
Temperature control is in the See Setting the Temperature Control Section.
OFF position.
Freezer may not be p_ugged in, Ensure plug is tightly pushed into outlet.
or plug may be loose.
House fuse blown or tripped Chack/repface fuse with a 15 amp time-dstay fuse. Reset
circuit breaker, circuit breaker.
Power outage. Check house lights. CStl local Electric Company.
FP_ezer tuns too much or too Room or outside weather is hot.
_ong.
Freezer has recently been
disconnected for a period of
time.
Large amounts of warm or hat
food have been stored recently.
Doors are opened too frequently
or too long.
Freezer door may be siightJy
open.
Temperature Control is set too
low.
Freezer gasket is dirty, worn,
cracked, or poorly fitted.
•tt's normal for the freezer to work harder under these
conditions.
tt takes 4 hours for the freezer to cost down complete_
Warm food will cause freezer to run more unti_the
desired temperature is reached.
Warm air entering the freezer causes it to run more.
Open doors less often.
See "DOOR PROBLEMS" Section.
Turn control knob to a warmer settfag. Allow several hours
for the temperafore to stebilize.
Clean or change gasket. Leaks in the door seal w_llcause
freezer to run fonger in order to m_Jctain desired
temperature.
Interior Freezer temperature is Temperature Control is set too Turn the control to a warmer setting. A_{owseveral hours
too cold. low. for the temperature to stabilize.
Temperature Control is set too
warm.
Door is kept open too long or is
opened too frequentl_
Door may not be seating
properl_
Large amoucts of warm or hot
food may have been stored
recenU_
Freezer has recency been
disconnected for a period of
time.
Interior Freezer temperature is
too warm.
Turn control to a colder setting. Allow several hours for the
temperature to stabilize.
Warm air enters the freezer every time the door is
opened. Open the door tess often.
See "DOOR PROBLEMS" Section.
Wait unti_the freezer has had a chance to reach its
selected temperature.
Freezer requires 4 hours to cool down completely.
FP_ezer external surface The external freezer walls can This is norma! while the compressor works to transfer
temperature is warm. be as much as 30_F warmer heat from inside the freezer cabinet.
tha_ room temperature.
SOUND AND NOISE
Louder sound levels whenever Modern freezers have increased This is normst.When the surrounding noise level is low,
fP_.zer is on. storage capacity and more you might hear the compressor running wMle it cools the
stable temperatures.They interior.
require a high eff_stency
compressor.
Longer sound levels when Freezer operates at higher This is normal Sound will leve_off or disappear as freezer
compressor comes on. pressures during the start of the contfaues to run.
ON cyste.