15
Shaver does not
charge
completely and
keeps blinking.
Ambient temperature is out of
valid range.
Recommended ambient temperature
for charging is 41 °F to 95 °F / 5 °C to
35 °C.
Unpleasant
smell from the
shaver head.
1. Shaver head is cleaned
with water.
2. Cleaning cartridge is in use
for more than 8 weeks.
1. When cleaning the shaver head with
water only use hot water and from
time to time some liquid soap
(without abrasive substances).
Remove Foil & Cutter cassette to let
it dry.
2. Change cleaning cartridge at least
every 8 weeks.
Battery
performance
dropped
significantly.
1. Foil and cutter are worn
which requires more power
for each shave.
2. Shaver head is regularly
cleaned with water but not
lubricated.
1. Renew Foil & Cutter cassette.
2. If the shaver is regularly cleaned
with water, apply a drop of light
machine oil on top of the foil once a
week for lubrication.
Shaving
performance
dropped
significantly.
1. Foil and cutter are worn.
2. Shaving system is
clogged.
1. Renew Foil & Cutter cassette.
2. Soak the Foil & Cutter cassette into
hot water with a drop of dish liquid.
Afterwards rinse it properly and tap
it out. Once dry apply a drop of light
machine oil on the foil.
Shaver head is
damp.
1. Drying time after automatic
cleaning was too short.
2.
Drain of the Clean & Charge
station is clogged.
1. Clean directly after shaving to allow
enough time for drying.
2. Clean the drain with a wooden
toothpick.
Clean & Charge Station
Cleaning does
not start when
pressing the
start button.
1. Shaver is not placed
properly in the Clean &
Charge Station.
2. Cleaning cartridge does
not contain sufficient
cleaning fluid (display
blinks red).
3. Appliance is in stand-by
mode.
1. Insert shaver into the Clean &
Charge Station and push it to the
rear side of the station (contacts of
the shaver need to align with
contacts in the station).
2. Insert new cleaning cartridge.
Press the start button again.
3. Press the start button again.
Increased
consumption of
cleaning fluid.
Drain of the Clean &
Charge station is clogged.
– Clean the drain with a wooden
toothpick.
– Regularly wipe the tub clean.