Loading ...
Loading ...
Loading ...
Installation
30
Adjusting the minimum setting for natural
gas
Light the burner and turn it to the minimum
position. Extract the gas tap knob and turn
the adjustment screw next to the tap rod
(depending on the model) until the correct
minimum flame is achieved.
Refit the knob and verify that the burner
flame is stable. Turn the knob rapidly from
the maximum to the minimum setting: the
flame should not go out. Repeat the
operation on all gas taps.
Adjusting the minimum setting for LPG
• Tighten the screw located at the side of
the tap rod clockwise all the way.
Lubricating the gas taps
Over time the gas taps may become difficult
to turn and get blocked. Clean them
internally and replace the lubrication
grease.
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label fixed to the appliance with
the one corresponding to the new
gas. The label is inserted inside the
nozzle pack (where present)
Lubrication of the gas taps should
be performed by a specialised
technician.
Loading ...
Loading ...