Troubleshooting
The following symptoms do not indicate malfunction.
Symptom Cause
POWER indicator blinks before the unit is
switched on.
This is a preliminary step in preparation for the
operation when the ON timer has been set.
When ON Timer is set, the unit may start earlier (up
to 35 minutes) before the actual set time in order to
achieve the desired temperature on time.
POWER indicator blinks during HEAT
mode with no warm air supply (and ap is
closed).
The unit is in defrost mode (and AIR SWING is set
to AUTO).
TIMER indicator is always on.
The timer setting repeats daily once set.
Operation is delayed a few minutes after
restarting.
The delay is a protection to the unit’s compressor.
Indoor fan stops occasionally during
heating operation.
To avoid unintended cooling effect.
Indoor fan stops occasionally during
automatic fan speed setting.
This helps to remove the surrounding odour.
Air ow continues even after operation has
stopped.
Extraction of remaining heat from the indoor unit
(maximum 30 seconds).
The room has a peculiar odour.
This may be due to damp smell emitted by the wall,
carpet, furniture or clothing.
Cracking sound during operation.
Changes of temperature caused the expansion/
contraction of the unit.
Water owing sound during operation.
Refrigerant ow inside the unit.
Mist emerges from indoor unit.
Condensation effect due to cooling process.
Outdoor unit emits water/steam.
Condensation or evaporation occurs on pipes.
Louder noise at outdoor unit during early
operation of i AUTO-X.
The compressor and fan rotate at higher speed to
boost cooling performance during initial operation.
Discoloration of some plastic parts.
Discoloration is subject to material types used in
plastic parts, accelerated when exposed to heat,
sun light, UV light or environmental factor.
Check the following before calling for servicing.
Symptom Check
Operation in HEAT/COOL mode is not
working ef ciently.
Set the temperature correctly.
Close all doors and windows.
Clean or replace the lters.
Clear any obstruction at the air inlet and air outlet
vents.
Noisy during operation.
Check if the unit has been installed at an incline.
Close the front panel properly.
Remote control does not work.
(Display is dim or transmission signal is
weak.)
Insert the batteries correctly.
Replace weak batteries.
The unit does not work.
Check if the circuit breaker is tripped.
Check if timers have been set.
The unit does not receive the signal from
the remote control.
Make sure the receiver is not obstructed.
Certain uorescent lights may interfere with signal
transmitter. Please consult authorised dealer.