Fault Possible cause Remedial action
Ice maker is not producing any ice.
The ice cube container is in the false
position.
The water pressureis too tow.
The freezer compartment temperature
is too high.
A wrong water valve has been
instattedt.
Reinsertthe container and slide it backwardsto the end
position (seesection "Variable interior design").
Check water pressure.The water pressure must be
between 25 and 120 p.s.i. (1.72-8.25 bar).
Check temperature of the freezer compartment.
tf required, lower the temperature.
Self-tapping valvesand 3/16 inch (4.76 ram) saddle
valves reduce the water pressure and may eventually
block the pipe.
The manufacturer is not liable for damage to
property due to an incorrect installation or water
connection.
The ice maker is not producing
enough ice or the ice cubes are
misshapen.
The water pressureis too tow.
The freezer compartment temperature
is too tow.
Changethe water filter.
Check water pressure.The water pressure must be
between 25 and 120 p.s.i. (1.72-8.25 bar).
Check temperature of the freezercompartment, tf
required increase the temperature.
Instructionsfor changing the water filter can be found in
the enclosedinstallation instructions.
Ice is forming in the supply hose to
the ice maker.
Water is flowing out of the
appliance.
Closeshut-off valveimmediately.
The water pressureis too tow.
The freezer compartment temperature
is too high.
The water pipe in the appliance is
defective.
The water pressureis too tow.
A wrong water valve has been
installed.
Check water pressure.The water pressure must be
between 25 and 120 p.s.i. (1.72-8.25 bar).
Check temperature of the freezercompartment, tf
required, lower the temperature.
Call customer service immediately.
The valve may leak if the water pressure is too tow.
The water pressure must be between 25 and 120 p.s.i.
(1.72-8.25 bar).
Self-tapping valvesand 3/16 inch (4.76 ram) saddle
valves reduce the water pressure and may eventually
block the pipe.
The manufacturer is not liable for damage to
property due to an incorrect installation or water
connection.
25