Bromic BH01100041 Heating

User Manual - Page 18

For BH01100041.

PDF File Manual, 27 pages, Read Online | Download pdf file

BH01100041 photo
Loading ...
Loading ...
Loading ...
18
www.bromic.com/
heating
The Dungs GB Valve is a multifunctional Gas Control with
combined regulator and safety shutoff valves.
The pressure regulator includes a servo regulator to regulate
pressure fluctuations in the mains supply. This ensures a
precise volume flow and constant injector pressure.
To shut down the pressure regulator turn the setting device
25 times clockwise until a soft click can be heard.
Standard Specifications
TECHNICAL DATA
Gas Connection 1/2” RP
Max Inlet Pressure 65 mbar
Pressure Range 2.5mbar to 38mbar
Nominal Flow 3,3 m3/h (Air)
Ambient temperature 5 °F to -158 °F
32 °F to -158 °F at LPG
Automatic shut-off valves Class B as per EN 126
Group 2
Pressure Regulator Class C
Degree of protection IP40
OPERATION DATA - DUNGS GAS VALVE
TECHNICAL DATA
Opening Time Fast Opening <1sec
Slow Opening <10 sec
Closing Time <1 sec
Voltage Frequency ~(AC) 50 - 60 Hz 24 V +10
% – 15 %
Load of coil (24 V, 230 V) 2 x 5,5 VA
Electrical connection Molex System connection
coil or Option: Connection
box with integrated cable
Installation position Solenoid at any position
between vertical and hori-
zontal axis.
OPERATION DATA - WHITE RODGERS VALVE
The White Rodgers Gas Valve is a compact multi-functional
control which incorporates an adjustable direct acting
pressure regulator. It operates on 24V.
Standard Specifications
Inlet Screen – will filter to 180 microns
Ambient Temperature Range of 32°F to -140°F
Compact Size: 86.5mm x 63.5mm x 65.9mm
50mb Pressure Rating
Class ‘B’ Group 2 Direct Acting Solenoid Valves with
high sealing force
3/8” x 3/8” (BSP PI.) Inlet and Outlet
Opening time < 0.25 seconds
Closing time < 0.25 seconds
Earthing terminal – 6mm spade tab
Tamper resistant screws
Top mounted coils and electronics that can be field
replaced without entering the gas stream.
TECHNICAL DATA
Max Working pressure 50 mbar
Installation group Group 2
Operating Temperature 32°F to -140°F
Regulator adjustment range 9.2 to 13.7 mbar
Voltage Ratings 24VAC
50/60Hz