14
Three Draining Functions
(Forced Draining, Automatic Draining, Water Draining)
Forced drainage
function
Must be implemented to prevent freezing in winter storage. Use this function for
cleaning the inside.
- Turn on the power switch and press the "DOWN + SET" button simultaneously for 3
seconds with any signal on the FND display. (30 seconds)
Automatic drain
function (F. 5)
Turn on the power switch and turn the ice making switch to "ICE MAKING" to start the
operation.
FND 1
st
, 2
nd
digits (drain time): 2 seconds (oF ~ 99 seconds, Set Unit of one
second).
FND 3
rd
, 4
th
digits (drain interval): 1.0 hour.
(0.5 to 9.5 hours, every 30 minutes)
Initial water draining
function (F. 4)
Turn the power switch off and then on again (the ICE MAKING-OFF-WASH switch at
"ICE MAKING" position) to operate the function.
Clean the water line and ice making cylinder thoroughly.
FND 1
st
, 2
nd
(drain time) 30 seconds (oF ~ 99 seconds, Set Unit of one second).
Water supply operation to high water level after drainage.
FND 3
rd
, 4
th
digits (number of repetition) Reference: 3 times (1 ~ 9 times).
Stop switch
With the power switch turned on, turn the "ICE MAKING-OFF-WASH" switch to center OFF, then the
ice making stops and the motor runs for another 60 seconds.
This function protects the motor by removing the ice remaining in the product.
If you sell the remaining ice even when it is OFF, ice discharging will be done.