25
provide detailed instructions on affiliation and correct use.
Note: the Speed 4 (and the Speed 5, where applicable) if
selected, will activate for a limited period of time after which
Speed 2 is automatically enabled.
Remote control connection (if applicable)
Once the remote control has been connected, this will be
displayed on the hood:
both LEDs flash.
Note: Using the remote control, delayed shut-down can be
programmed based on the aspiration speed (power) enabled
at that moment:
Speed 1 (low aspiration): 20 minutes
Speed 2 (medium aspiration): 15 minutes
Speed 3 (high aspiration): 10 minutes
Filter Saturation indicator lights
At regular intervals, the LEDs on the hood indicate the need to
carry out filter maintenance.
Note: The filter saturation signal is visible for a few seconds
when the hood is switched on; within this time, the
saturation indicator lights must be reset.
Flashing Green LED: carry out maintenance on the
grease filter.
Red flashing LED: carry out maintenance on the charcoal
filter (only for hoods operating in "Filtration Version").
Note: Run the "RESET FILTRES" command via the
remote control.
Activating/deactivating the filter saturation indicator
light
Note: Run the procedure with the hood switched off. The
charcoal filter saturation indicator light is usually
deactivated.
If no control is given within maximum 10 sec, the hood
automatically exits this function, at any time, and returns
to the previous state.
Press and hold the B+C keys (Simultaneously) to enter
the setup menu:
Briefly press button C to select the filter to be set up:
Grease filter:Green
Charcoal filter: Red
Briefly press button B to activate (the 2nd LED flashing)
or deactivate (2nd LED off).
Note: the LEDs light up for a limited number of seconds
after which they turn off to indicate that the indicator light
has been activated (or deactivated).
This home appliance is designed to be used with a
Window sensor KIT (not supplied by the manufacturer).
By installing the Window sensor KIT (only if used in SUCTION
mode), the air suction unit will stop working whenever the
window in the room in which the KIT is used, is closed.
We recommend that you purchase the FDS - 100
Elektrotechnik Schabus KIT, which is available at the
Elektrotechnik Schabus authorised centres, or directly on the
website www.elektrotechnik-schabus.de.
The electrical connection of the Window sensor KIT
must be carried out by qualified and specialised technical
staff.
WARNING: place the KIT in an area that cannot be
accessed by the user after installation.
The manufacturer of this home appliance denies all
liability for any inconvenience, damage, fire caused by
defects and/or malfunctions and/or incorrect installation
of the KIT.
Maintenance
Cleaning
Clean using ONLY a cloth dampened with neutral liquid
detergent. DO NOT CLEAN WITH TOOLS OR
INSTRUMENTS. Do not use abrasive products. DO NOT USE
ALCOHOL!
Panel
Fig. 14-17
The panel for perimeter suction should always be left closed
and should only be opened in case of maintenance
interventions (eg cleaning or replacing filters).
Grease filter
Fig. 14-17
Traps cooking grease particles.
This must be cleaned once a month (or when the filter
saturation indication system – if envisaged on the model in
possession – indicates this necessity) using non aggressive
detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolor
slightly, but this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Charcoal filter (filter version only)
Fig. 15
It absorbs unpleasant odors caused by cooking.
The activated carbons are incorporated into a ceramic
structure, making them easily and completely accessible by
impurities, thus creating a large absorption surface.
The ceramic activated carbon filters will become saturated
after a more or less prolonged period of use, depending on
the type of cooking and frequency with which the grease filters
are cleaned. These odour filters can be thermally regenerated
every 2/3 months in an oven preheated to 200°C for 45
minutes. Regeneration allows a maximum filter lifespan of 5
years.
Replacing lamps
The hood is equipped with a lighting system based on LED
technology.
The LEDs guarantee an optimum lighting, a duration up to 10
times as long as the traditional lamps and allow to save 90%
electrical energy.
For replacement, contact the technical service.