Installation
107
EN
The appliance can work in the following
modes (see cable sections)
220-240 V 2~
3 x 2.5 mm² three-pole cable.
220-240 V 3~
4 x 2.5 mm² four-pole cable.
220-240 V 1N~
3 x 2.5 mm² three-pole cable.
380-415 V 2N~
4 x 2.5 mm² four-pole cable.
380-415 V 3N~
5 x 1.5 mm² five-pole cable.
5.5 Access to the terminal board
To connect the power supply cable, access
to the terminal board on the rear cover:
1. Remove the screws securing the lid to the
rear cover.
2. Slightly turn the lid and remove it from its
housing.
The values indicated above refer
to the cross-section of the internal
lead.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).