Kenmore 153326030 water heater

User Manual - Page 4

For 153326030.

PDF File Manual, 28 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Customer Responsibilities
Thank You for purchasing a Sears water heater.
Properly installed and maintained, it should give you years of
trouble free service. If you should decide that you want the new
water heater professionally installed by Sears call the local
Service Center or any Sears store. They will arrange for prompt,
quality installation by Sears authorized contractors.
The installation must conform with the instructions in this
manual; electric company rules; and Local Codes, or in the
absence of Local Codes, with the current edition of the
National Electrical Code NFPA 70. This publication is available
from your local government or public library or electric compa-
ny or by writing Underwriters Laboratories Inc., 333 Pfingsten
Road, Northbrook, 1L60062.
Abbreviations Found In This Instruction Manual
U.L. - Underwriters Laboratories Inc., 333 Pfingsten Rd.,
Northbrook, IL 60062
NEC - National Electrical Code
ANSI - American National Standards Institute
Read the "Safety Precautions" section, page 2 of this manual
first and then the entire manual carefully, lfyou don't follow
the safety rules, the water heater will not operate properly. It
could cause DEKFH, SERIOUS BODILY INJURY AND/OR
PROPERTY DAMAGE.
This manual contains instructions for the installation, opera-
tion, and maintenance of this electric water heater. It also con-
tains warnings throughout the manual that you must read and
be aware All warnings and all instructions are essential to
the proper operation of the water heater and your safety. Since
we cannot put everything on the first few pages, READ THIS
ENTIRE MANUAL BEFORE ATTEMPTING TO
1NKIALL OR OPERATE THE WKFER HEATER.
If after reading this manual you have any questions or do not
understand any portion of the instructions, call Sears
Service Center.
Carefully plan the place where you are going to put the water
heater. Correct electrical wiring and connections are very
important in preventing death from possible electrical shock
and fires. Examine the location to ensure the water heater com-
plies with the "Facts to Consider About the Location" section.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation procedures.
Instructions may be obtained from your local dealer, whole-
saler, public utilities or California Office of the State Architect,
400 P Street, Sacramento, CA 95814.
Massachusetts Code requires this water heater to be installed
in accordance with Massachusetts 248-CMR 2.00: State
Plumbing Code and 248-CMR 5.00.
Product Specifications
MODEL
NUMBER
153.316030
153.316132
153.316232
153.316330
153.316630
153.326030
153.326230
153.326330
TANK
CAPACITY
IN GALLONS
19.9
10
19.9
30
6
19.9
19.9
30
DIMENSIONS IN INCHES
DIAMETER HHGHT
18" 31_"
18" 18"
22" 22_"
22" 30"
16" 17"
18" 35"
22" 22_"
22" 30"
RECOVERY RATE
GALS. PER HOUR
@ 90°E RISE
7.5
7.5
7.5
7.5
7.5
9.1
9.1
9.1
ELEMENT
WATTAGE
120Vok 240Vok
1650 -
1650 -
1650 -
1650 -
1650 -
2000
2000
2000
MINIMUM
WIRE SIZE*
(GAUGE)
12
12
12
12
12
14
14
14
MAXIMUM FUSE
OR CIRCUIT
BREAKER
SIZE (AMPS)
20
20
20
20
20
10
10
10
*Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electri-
cal code.