GE - General Electric ZICP360SRCSS GE bottom-mount refrigerator

User Manual - Page 17

For ZICP360SRCSS.

PDF File Manual, 20 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Performance Data Sheet
SmartWater Filtration System
H WF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI42/53.*
100% safety factors built in for unmetered usage)
Parameter USEPA
MCL
Chlorine
T&O
Particulate**
Parameter
Turbiditg
Cgsts
Asbestos
Leadat pH 6.5
Leadat pH 8.5
Hercurg at pH 6.5
Hercurg at pH 8.5
Alachlor
Lindane
2,4-D
Toxaphene
Benzene
Carbofuran
1,4dichlorobenzene
Atrazine
Influent
Challenge Concentration
2.0rag/L± 10%
> 10,000 particles/mL
USEPA
MCL
0.5NTU
_>99.95% Reduction
_>99% Reduction
0.015 mg/L
0.015 mg/L
0.002 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.075 mg/L
0.003 mg/L
Standard No. 42: Aesthetic Effects
Influent Effluent
Average Average Maximum
1.96mg/L 0.06 mg/L 0.11 mg/L
6,400,000#/mL 58,833#/mL 150,000#/mL
Standard No. 53: Health Effects
Influent
Challenge Concentration
11+ 1 NTU***
Hinimum 50,000 L
107to 108fibers/L;> 101]m
0.15rag/L+ 10%
0.15rag/L+ 10%
0.006 mg/L+ !0%
0.006 mg/L+ !0%
0.04rag/L+ 10%
0.002 mg/L + 10%
0.210 rag/L+ 10%
0.015 rag/L+ 10%
0.015 rag/L+ 10%
0.080 mg/L + 10%
0.225 mg/L+ 10%
0.009 mg/L + 10%
Influent
Average
10.5NTU
118,750#/L
57 HF/L
0.1567 mg/L
0.1433 mg/L
0.0059 mg/L
0.0057 mg/L
0.0367 mg/L
0.0020 mg/L
0.2033 mg/L
0.0160 mg/L
0.0145 mg/L
0.0830 mg/L
0.2283 mg/L
0.0087 mg/L
Effluent
Average Maximum
0.!4 NTU 0.28 NTU
< !#/L 4#/L
0.996 HF/L < 1 HF/L
< 0.001mg/L < 0.001 mg/L
< 0.001mg/L < 0.001 mg/L
0.000350 mg/L 0.0007 mg/L
0.000325 mg/L 0.0006 mg/L
0.00023 mg/L 0.0004 mg/L
<0.00002 mg/L <0.00002mg/L
0.00337mg/L 0.011000mg/L
0.00100 mg/L 0.001000 mg/L
0.000500 mg/L 0.000500 mg/L
0.001000 mg/L 0.001000 mg/L
0.000500 mg/L 0.000500 mg/L
< 0.0005 mg/L < 0.0005 mg/L
% Reduction
Average Minimum
96.77% 94.74%
99.14% 97.97%
% Reduction
Average Minimum
98.54% 97.20%
> 99.99% > 99.99%
99.60% 99.39%
99.36% 99.29%
99.30% 99.29%
94.70% 87.50%
93.20% 89.29%
99.34% 98.67%
99.00% 98.95%
98.32% 94.50%
93.44% 91.67%
96.51% 95.83%
98.78% 98.65%
99.78% 99.77%
94.22% 93.33%
Min. Required
Reduction
> 50%
>85%
Min. Required
Reduction
0.5 NTU
> 99.95%
_>99%
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.04mg/L
0.075 mg/L
0.003 mg/L
* Tested using a flow rate of 0.50 gpm; pressure of 60 psig; pH of 7.5 +_0.5; temp. of 68 ° +_5°F (20 ° +_3°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbiditg units
Operating Specifications
[] Capacitg:certified for up to 300 gallons (1135I);up to six months for models without a replacement filter indicator light;
up to one gear for models with a replacement filter indicator light
[] Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
[] Temperature: 33-100°F (0.6-38°C)
[] Flow rate: 0.5 gpm (1.9Ipm)
General Installation/Operation/Maintenance Requirements
[] Flush new cartridge at full flow for 3 minutes to purge out trapped air.
[] Replace cartridge when the indicator light flashes or water flow rate is reduced on non-indicator units.
Special Notices
[] Installation instructions, parts and service availabilitg, and standard warrantg are included with the product when shipped.
[] Thisdrinking water sgstem must be maintained according to manufacturer's instructions, including replacement of filter cartridges.
[] Do not use with water that is microbiologicallg unsafe or of unknown qualitg without adequate disinfection before or
after the sgstem. Sgstems certified for cgst reduction mag be used on disinfected water that mag contain filterable cgsts.
[] The contaminants or other substances removed or reduced bg this water treatment sgstem are not necessarilg in gout wateE
[] Check for compliance with the state and local laws and regulations.
[] Note that while the testing was performed under standard laboratorg conditions, actual performance mag varg. Sgstems must
be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
Standard No. 42: Aesthetic Effects
Chemical Unit
Chlorine Taste and Odor
Mechanical Filtration Unit
Particulate Reduction, Class I
Sgstem Tested and Certified bg NSFInternational against ANSI/NSF Standard 42 & 53 for the reduction of:
Standard No. 53: Health Effects
Chemical Reduction Unit
Alachlor and Atrazine Reduction
Benzene and Carbofuran Reduction
1,4dichlorobenzene and 2,4-D Reduction
Leadand Lindane Reduction
Mercurg and Toxaphene Reduction
Mechanical Filtration Unit
Turbiditg Reduction
Cgst and Asbestos Reduction
Manufactured for: General Electric Compang, Louisville, KY40225 17