Electrical connection
Connect to individual Brunch
Circuit.
Do not use an adapter.
Do not use an extension cord.
Do not remove ground prong.
Your dryer comes with a power
supply cord:
- ULlisted in the USA,
- CSA listed in Canada.
When installing the receptacle for
the dryer cord, ensure that the
power supply cord is accessible
when the dryer is in the installed
position.
The power cord should only be
replaced by a qualified person.
Use a 4-wire power supply cord.
Grounding instruction
The dryer comes with a cord which
has an equipment grounding
conductor and a grounding plug.
The plug must be plugged into an
appropriate outlet which has been
properly installed and grounded in
accordance with all local
regulations and ordinances.
Improper connection of the
equipment grounding conductor
may result in electric shock.
Have the appliance checked by
a qualified electrician or service
technician if you are in doubt as
to whether the dryer has been
properly grounded.
Integrated socket
This appliance is equipped with a
socket for connecting a washer
without fuses. Only the listed
washer may be connected. For all
other connections Bosch will
assume no liability.
Use copper conductors only.
Connect to a 30 A minimum
individual branch circuit, fused at
30 A maximum.
Use receptable only for:
208 - 240 VAC 60 Hz 11 A
washer: WFR2460UC,
WFL2060UC.
Exhaust air connection
You can use the exhaust air set
which can be obtained from
customer service or your local
dealer (WTZl 130).
Also any products which are
commercially available can be used
for the exhaust air duct:
- flexible tubes,
- galvanised sheet metal ducts or
tubes,
- connection, transfer and
by-pass adapters for use in flat
duct or tubular ducting
systems,
- wall boxes for ventilation into
the open air or into an air shaft,
- adapters for rectangular ducts,
- rectangular ducts or plastic
tubesone-way flap.
1. To reduce the risk of fire, this
dryer MUST BE EXHAUSTED
OUTDOORS.
2. To reduce the risk of fire, do
not use the ductwork longer
than recommended.
3. DO NOT use a plastic or
non-metal duct with this dryer.
4. DO NOT use a duct smaller
than 4 inches in diameter.
5. DO NOT use exhaust hoods
with magnetic latches.
6. DO NOT exhaust the dryer into
a chimney, furnace cold air
duct, attic, crawl space, or any
other ductwork used for
venting.
7. DO NOT install a flexible duct
in an enclosed wall, ceiling or
floor.
8. DO NOT crush or kink the
duct.
9. Do clean and inspect the
exhaust system on a regular
basis; at least once a year.
10. The exhaust duct must
terminate in a manner to
prevent back drafts or entry of
birds or other wildlife.
The Bosch dryers are intended to
be vented outdoors. To prevent
build-up of moisture and
accumulation of lint indoors, as well
as to maintain maximum drying
efficiency, it is recommended that
the dryer is vented outdoors.
[-_ Position the exhaust air duct so
that there is no counter-
pressure (e.g. from wind) on the
exhaust outlet.
All materials must be
heat-resistant up to 80 °C and
humidity-resistant.