Safety and warning information
Installation safety
WARNING
To reduce risk of fire, electric shock, personal injury, or death, observe these precautions:
The cooktop should be installed and properly grounded by a
qualified installer, as
specified in this manual. Adjustments and service should be performed only by
qualified installer or service technician.
Do not service/modify/replace the cooktop or any part of it unless directed in this
manual. All other service should be performed by a qualified techni
cian.
Use only new, flexible connectors when installing the cooktop.
Ensure the cooktop's hold-down brackets are properly installed.
(See
pg.
26
.
)
Remove all tape and packaging materials.
After unpacking the cooktop,
remove all accessories from inside and around it.
(Cautiously handle the heavy grates.)
Verify that nothing came loose during shipping.
Ensure the cooktop is correctly installed/adjusted by a qualified service technician or
installer for the type of gas (natural or LP) you will use. For the cooktop to use
LP gas, a qualified installer/technician must replace every burner orifice with the
provided LP orifice set, and reverse the GPR adapter. The qualified agency performing
this work shall be responsible for the conversion.
Installation must conform to local codes or in their absence, to the National Fuel Gas
Code, ANSI Z223.1/NFPA.54, latest edition. In Canada, installation must conform with
the current Natural Gas and Propane Installation Code, CAN/CGA-B149.1, or the
current Propane Installation Code, CAN/CGA-B149.2, and with local codes where
applicable. This cooktop has been design-certified by ETL according to ANSI Z21.1,
latest edition, and Canadian Gas Association according to CAN/CGA-1.1, latest edition.