Electrolux EI30BM5CHSC microwave/hood combo

INSTALLATION INSTRUCTIONS - Page 2

For EI30BM5CHSC.

PDF File Manual, 24 pages, Read Online | Download pdf file

EI30BM5CHSC photo
Loading ...
3
ELECTRICAL
GROUNDING
INSTRUCTIONS
This
appliance
must
be
grounded.
This
oven
is
equipped
with
a
cord
having
a
grounding
wire
with
a
grounding
plug.
It
must
be
plugged
into
a
wall
receptacle
that
is
properly
installed
and
grounded
in
accordance
with
the
National
Electrical
Code
and
local
codes
and
ordinances.
Inthe
event
of
an
electrical
short
circuit,
grounding
reduces
risk
of
electric
shock
by
providing
an
escape
wire
for
the
electric
current.
WARNING
-
Improper
use
of
the
grounding
plug
can
result
in
a
risk
of
electric
shock.
ELECTRICAL
REQUIREMENTS
The
oven
is
equipped
with
a
3-prong
grounding
plug.
DO
NOT
UNDER
ANY
CIRCUMSTANCES
CUT
OR
REMOVE
THE
GROUNDING
PIN
FROM
THE
PLUG.
DO
NOT
USE
AN
EXTENSION
CORD.
If
the
power
supply
cord
is
too
short,
have
a
qualified
electrician
or
serviceman
install
an
outlet
near
the
appliance.
The
Power
Supply
Cord
and
plug
must
be
connected
to
a
separate
120
Volt
AC,
60
Hz,
15
Amp,
or
more
branch
circuit,
single
grounded
receptacle.
The
receptacle
should
be
located
inside
the
cabinet
directly
above
the
Microwave
Oven
mounting
location
as
shown
in
Figure
2.
NOTE:
1.
If
you
have
any
questions
about
the
grounding
or
electrical
instructions,
consult
a
qualified
electrician
or
serviceperson.
2.
Neither
Electrolux
nor the
dealer
can
accept
any
liability
for
damage
to
the
oven
or
personal
injury
resulting
from
failure
to
observe
the
correct
electrical
connection
procedures.
~~
Ground
a
Receptacle
_/
oo
0
Opening
for
Power
Cord
|
|
Figure
2
4
HOOD
EXHAUST
DUCT
When
the
hood
is
vented
to
the
outside,
a
hood
exhaust
duct
is
required.
All
ductwork
must
be
metal;
absolutely
do
not
use
plastic
duct.
Check
that
all
connections
are
made
securely.
Please
read
the
following
carefully:
EXHAUST
CONNECTION:
The
hood
exhaust
has
been
designed
to
connect
to
a
standard
3
'/4"
x
10"
rectangular
duct.
If
round
duct
is
required,
a
rectangular-to-round
adapter
must
be
used.
REAR
EXHAUST:
If
a
rear
or
horizontal
exhaust
is
to
be
used,
care
should
be
taken
to
align
the
exhaust
with
the
space
between
the
studs,
or
wall
should
be
prepared
at
the
time
it
is
constructed
by
leaving
enough
space
between
wall
studs
to
accommodate
exhaust.
MAXIMUM
DUCT
LENGTH:
For
satisfactory
air
movement,
the
total
duct
length
of
3 1/4"
x
10"
rectangular
or
6"
diameter
round
duct
should
not
exceed
140
feet.
Elbows,
adapters,
wall
caps,
roof
caps,
etc.
present
additional
resistance
to
air
flow
and
are
equivalent
to
a
section
of
straight
duct
which
is
longer
than
their
actual
physical
size.
When
calculating
the
total
length,
add
the
equivalent
lengths
of
all
transitions
and
adapters
plus
the
length
of
all
straight
duct
sections.
Figure
3
shows
the
approximate
feet
of
equivalent
length
of
some
typical
ductwork
parts.
Use
the
values
in
parentheses
for
calculating
air
flow
resistance
equivalent,
which
should
total
less
than
140
feet.
NOTE:
Furnace
duct
sealing
tape
is
recommended
to
seal
duct
connections
to
the
Exhaust
Dampener
Assembly.
90°
Elbow
(10
ft.)|
45°
Elbow
(5
ft.}}
Adaptor
(5
ft.)
|
10"
Wide
Elbow
(10ft)
©
Z
90°
Elbow
(25
ft.)}
45°
Elbow
(5
ft.)}
Wall
cap
(40
ft.)|
Roof
cap
(24
ft.)
S
|S
GS
<=>
Figure
3
Loading ...