SolarPod 1004 2200-Watt Plug & Play Off Grid with charger

User Manual - Page 4

For 1004.

PDF File Manual, 5 pages, Read Online | Download pdf file

1004 photo
Loading ...
Loading ...
Loading ...
Mouli Engineering Inc. © 2014; U.S. Patent No. 8,716,889 Rev. 5 May 4, 2014
Model #1004:
All terminals are labeled and must be torqued to enable good contact with the terminator of the
devices.
Model #1005 & 1006:
All terminals are labeled and must be torqued to enable good contact with the terminator of the
devices.
15. Attach the other end female without weather proof to the inverter with the male twist lock without
weather proof boot.
Connect the wires as labelled on the wire. Ensure the bolts are torqued for best contact.
16. Power up sequence:
a. Ensure all DC breakers in the DC Circuit Breaker Box are off.
b. Turn on the Charge Controller to DC Circuit Breaker.
c. Turn on the Charge Controller to Battery Circuit Breaker.
d. Program the charge controller.
i. Language – English
ii. Nominal System Voltage : Model #1004 – 12V ; Model 1005 & 1006 – 48V
e. Turn on the PV Array by connecting the twist lock plugs.
i. Check charging status. Must indicate charging if enough Sun light present.
ii. Verify in the inverter there is 120V output between L1 and Neutral.
iii. Program float and absorption voltages for the DTM31 battery on the charge controller as
follows:
Model Float voltage Absorption Voltage
1004 13.5V 14.1
1005 and 1006 54V 56.4V
Charge
Controller
Inverter
DC Breaker
Box
Bat
Bat+
Charge
Controller
Inverter
DC Breaker
Box
AC Breaker
Box
Connection
to Solar
Connection to
Solar
Loading ...