DCS GDSBE1302L 30 Inch Griddle and Dual Side Burner with 244

User Manual - Page 10

For GDSBE1302L.

PDF File Manual, 16 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
9
GAS CONNECTION
Connection: 1/2” NPT male with 3/8” flare adapter Operating pressure: 4.0” W.C.
Supply pressure: 5” to 14” W.C. If in excess of 14” W.C. a step down regulator is required.
Check with your local gas utility company or local codes for instructions on installing gas
supply lines. Be sure to check on type and size of run, and how deep to bury the line. If the
gas line is too small, the griddle will not function properly. .
Connecting the fittings supplied with the double side burner/griddle.
Use joint compound on male threads only. Do not use joint compound on the flare end of the
1/2” NPT to 3/8” flare adapter. Ensure that the regulator arrow points in the direction of gas
flow towards the unit, away from the supply. Do not forget to place the installer-supplied gas
valve in an accessible location.
base of product
open top manifold
1/2” coupling
1/2” NPT x 2.0 nipple
1/2” NPT to 3/8”
flare adapter
to gas supply
1/2” NPT x 5.0 nipple
Regulator
Verify the type of gas supply to be used, either natural or LP, and make sure the marking
on the appliance rating plate agrees with that of the supply. The rating plate is located on
the underside of the drip tray. Never connect an unregulated gas line to the appliance. You
must use a gas regulator even if the supply is controlled.
Gas conversion kits are available from Customer Care. When ordering gas conversion kits,
have the model number, and the type of gas (natural or LP) from your side burner/griddle.
The appliance and its individual shut-off valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of
1/2 PSIG (3.5 kPa.). The appliance must be isolated from the gas supply piping system by
closing its individual manual shut-off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa.). The installation
of this appliance must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Installation in Canada must be in accordance with Natural Gas and Propane Installation
Code, CSA B149.1, and/or Propane Storage and Handling Code, B149.2 and local codes.
zz
Note:
zz
If it is evident there is excessive abrasion or wear, or the hose is cut, it must be
replaced prior to the outdoor cooking gas appliance being put into operation.
zz
The replacement hose assembly shall be that specified by the manufacturer.
Total gas consumption of the double side burner/griddle with all burners on HI.
GDSBE1-30: 49,000 Btu/hr
GAS REQUIREMENTS NATURAL GAS CONNECTION
Loading ...
Loading ...
Loading ...