Exhaustingthedryer.
ExhaustSystemRequirements
Useonly4" (10.2cm)diameter(minimum)rigidmetal
ductforbestpetformance,orflexiblemetalduct.Use
appr()ved vent 1100(1which has s_dng_(_utdampers
that open when the duer is in operation. When the
&yer stops, the (hmpers m_tomafically close to
prevent &afis and the entrance of insects and
roden/s. To avoid resuicfing the outlet, maintain a
mininmm of 12" (30.5 cm) clemance belween the
vent hood and the ground or any other obsu_uction.
If all rigid metal (h]ct cannot be used, then flexible
all-racial venting can be used, but it will re(h]ce the
maximum re(ommended duct length. See
A
AdditionalInstallationInstructionsfollo_fing. klk
Correct
Incorrect
ThedryerexhaustsystemMUSTBEEXHAUSTED
TOTHEOUTSIDEofthedwelling.
DONOTalh)wcombustible materials (for
example: clothing, &aperies/curtains, paper) to
come in contact with exhaust system.
ThedryerMUSTNOTbeexhaustedintoa gasvent,
chimney,a wall,a ceiling,a commonductwitha
kitchenexhaustoranyconcealedspaceofa
buildingwhichcanaccumulatelint,resultingina
firehazard.
DONOTexceed the length of duct pipe or
number of elbows allowed in the Maximum
Length charts. Ik_t can acommlate in the
exhaust system, plugging the sysmm and
creadng a fire hazard, as well as increasing
(h)4ng dines.
DONOTscreen the exhm_st ends oftim vent
sys[elil, nor use any screws or rivets to assemble
the exhm_st system. IJnt can become caught in
the screen, on the screws or rivets, clogging the
duct work and creating a fire hazmd aswell as
increasing (h)ing times. Use an approxvd vent
hood to terminate the (h_ctoutdoors, and seal
alljoints xdth duct rope. All male duct pipe
fittings MUSTbe installed (loxxllstream _dth
the fl()w of air.
WARNING: Thefollowing are specific requirements
for proper and safe operation of your dryer Failure
to follow these instructions can create excessive
drying times and fire hazards,
DONOT useplastic flexible duct to exhaust the
dryer.Excessive lint can build up inside exhaust
system and create a fire hazardand restrict air
flow, Restrictedair flow will increase drying
times, ff yourpresent system is made upofplastic
duct ormetal foil duct, replace it with rigid or
flexible metal duct, Ensurethe present duct is free
ofany lint prior to installing dryer duct
A
EXPLOSIONHAZARD.Do not install the duer
where gasoline or other flammables are kept
or stored. If the duer is installed in a gmage,
it must be a minimum of 18" (45.7 cm) above
the floor. Failure to do so can resuh in death,
explosion, fire or burns.
Provide an access for inspection and cleaning of
_tlle exhaust system, especially at turns, lnspe(rt
and clean at least once per year.
1)o not obstruct incoming or exhausted air.
Additional Installation Instructions
If all rigid melal (h_ct cannot be used, then flexible
all-racial venting can be used, but it will reduce the
maxinmm recommended (h]ct length. In special
installations when it is impossible m make a
connection with the ab()ve recommendations, then
UL-listedclothesdryertransitionductmay be used as
transition venting between the (hyer and wall
connection only. The use of this ducting will altect
(h)4ng lime.
ff flexibletransitionductisnecessary,onlyUL-listed
ductidentified forusewith clothesdryersisapproved.
Thefollowing directionsmustbe followed,
Use the shortest length possible.
Suetch the (h_ct to its maxinmm length,
° Do not crush or collapse.
Never use Uansition duct inside the wall, flooring,
ceiling or inside the &yer.
Avoid resting the (h_ct on shmp objecls.
° Venting nmst contorm to local building codes.