Heath Zenith HZ-4175-SA DualBrite Antique Silver Motion Sensing Outdoor Security Flood Light

INSTALLATION AND OPERATING INSTRUCTIONS - Page 5

For HZ-4175-SA. Also, The document are for others Heath Zenith models: HZ-4151-SA, HZ-4168-SA, HZ-4152-SA, HZ-4166-SA

PDF File Manual, 28 pages, Read Online | Download pdf file

HZ-4175-SA photo
Loading ...
Loading ...
Loading ...
5204030-03
Green
or Bare
Copper
Green
or Bare
Copper
Green
or Bare
Copper
OPTIONAL WIRING
is xture is provided with a sensor rated for 360 Watts. Since the xture is only rated 100 Watts, 260 Watts of ad-
ditional lighting may be controlled by this sensor.
When determining what a xture is rated for, do not simply look at the rating on the light bulb in the xture. Look at
the marking which species the maximum bulb wattage for which the xture is suitable.
Once you have selected the xtures to be connected and determined their maximum ratings, add these ratings up. For
instance, if you have 3 xtures rated 100 Watts, 150 Watts, and 75 Watts respectively, you have a total load of 325 Watts.
Wiring Diagram 1 – When wiring to control a standard light xture: Strip the motion sensors red wire and connect to
the standard lights black wire. Connect all white wires together. Total xture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 2 – When wiring to control another motion sensing light xture (Master / Slave): Strip the red wire in
both light xtures. Connect the red wire of the controlling (master) xture to the red and black wires of the controlled
(slave) xture. Connect all white wires together. Total xture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 3 – When wiring so either motion light turns on the both motion lights (Master / Master): Strip the
red wire in both light xtures. Connect the red wire of one xture to the red wire of the second xture. Note: In most
installations, an additional wire (same gauge as existing house wire) will have to be installed in the house to connect the
two xtures as master / master. Connect all white wires together and all black wires together. Total xture ratings must
not exceed 360 Watts (3.0 A).
Black
White
Light
Fixture
Light
Fixture
(Standard)
Master
Slave
Black
White
Light
Fixture
Light
Fixture
Red
Red
Wiring Diagram 1 Wiring Diagram 2
Wiring Diagram 3
Master Master
Black
White
Red
Light
Fixture
Light
Fixture