10 | PSH Plus www.stiebel-eltron-usa.com
INSTALLATION
Maintenance
Fault Cause Remedy
The water does not heat
up and the ON/OFF indi-
cator does not illuminate.
The high limit safety
cut-out has responded
because the controller is
faulty.
Remedy the cause of the
fault. Replace the con-
troller.
The high limit safety
cut-out has responded
because the temperature
has fallen below 5°F
(-15°C).
Press the reset button
(see diagram).
The water does not heat
up and the ON/OFF indi-
cator illuminates.
The heating element is
faulty.
Replace the heating el-
ement.
The water does not heat
up sufficiently and the
ON/OFF indicator illumi-
nates.
The temperature control-
ler is faulty.
Replace the temperature
controller.
The heat-up time is very
long and the ON/OFF in-
dicator illuminates.
The heating element is
scaled up.
Descale the heating el-
ement.
The T&P relief valve drips
when heating is switched
off.
The valve seat is contam-
inated.
Clean the valve seat.
Water pressure is too
high.
Install a pressure reduc-
ing valve.
An expansion vessel was
not installed.
Install an expansion
vessel in line with the
appliance (see plumbing
schematic).
Reset key, high limit safety cut-out
If the high limit safety cut-out has activated, it should be reset.
Shut off the circuit breaker connected to the appliance before
removing the bottom cover and resetting the switch.
15. Maintenance
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
Before any work on the appliance, disconnect all poles
of the appliance from the power supply.
If you need to drain the appliance, observe chapter 15.1, “Draining
the appliance, pg. 10.
15.1 Draining the appliance
WARNING Burns
Hot water may escape during the draining process.
If is necessary to drain the cylinder for maintenance or to protect
the whole installation from freezing, proceed as follows:
Close the shut-off valve in the cold water feed line.
Open the DHW valves of all draw-off points until the appli-
ance is fully drained.
Drain any residual water from the T&P relief valve.
15.2 Checking / replacing the sacrifi cial anode
Check the sacri cial anode after the fi rst year of use and re-
place if necessary.
Next, decide the time intervals at which further checks
should be carried out.
15.3 Descaling
Remove loose scale deposits from the water heater.
If necessary, descale the inner cylinder with commercially
available descaling agents.
Only descale the fl ange after disassembly and never treat the
cylinder surface and sacri cial anode with descaling agents.
15.4 Anti-corrosion protection
Ensure that while carrying out maintenance work the anti-cor-
rosion protection resistor (560 Ω) is not damaged or removed.
Reinsert the anti-corrosion protection correctly after replacement.
15.5 Replacing the power cable
DANGER Electrocution
The power cable must only be replaced (for example if
damaged) by a qualifi ed technician.