Activated Charcoal Filter (Recirculation Version)
This cannot be washed or regenerated, and must be changed when all the command LEDs
start to flash, or at least once every 4 months.
Activating the alarm signal
In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at
a later date.
Press and hold the Delay button (T4) on the keypad for 5 seconds and the following will be dis-
played:
Leds (L1-L2-L3) flash twice – Activated Charcoal Filter saturation alarm ACTIVATED.
Leds (L1-L2-L3) flash once – Activated Charcoal Filter saturation alarm DEACTI
VATED.
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• Press button T1 (see the paragraph on Use).
Changing the Filter
Remove the Metal grease filters.
Remove the saturated Activated Charcoal filter, as shown in
the figure.
Fit the new Filter, hooking it into place.
Replace the Metal grease filters.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
Remove the snap-on lamp cover by levering it from under the
metal ring, supporting it with one hand.
Remove the halogen lamp from the lamp holder by pulling
gently.
Replace the lamp with a new one of the same type, making
sure that you insert the two pins properly into the housings on
the lamp holder.
Replace the snap-on lamp cover.