REFRIGERATED GRIDDLE STANDS
OPERATIONS MANUAL
OPERATIONS W/ ELECTRONIC DIAL BEHIND GRILL
TEMPERATURE ADJUSTMENT PA & RA WITH
ELECTRONIC DIAL CONTROL
1. Remove grill to access temperature control knob: to remove
grill grasp top of the grill and pull outward to release the
grill.
2. The temperature control knob has 9 temperature positions
and an OFF position. Position 1 is the warmest position and
position 9 is the coldest position. To make the temperature
colder, turn the knob clockwise. To make the temperature
warmer, turn the knob counterclockwise. When the knob is
turned all the way counterclockwise, the unit will shut off.
LEDs
R Y G
Mains
Voltage
Compressor Description
X X
Off. Voltage bad. Cooling Demand.
X
Wait period (intelligent time delay).
Cooling Demand.
On. Voltage Good. Cooling Demand.
X
Defrost Mode.
X X
Probe #1 Fault. Voltage good.
Compressor Shuts Down or Cycles.
X X X
Test Mode.
X
Dial in “OFF” position.
X
X X
Voltage Bad. No Cooling Demand.
Probe #2 Fault. Voltage Good
X
X
On. Compressor Off due to Door Switch
Operation.
X
X
No Cooling Demand. Wait is On.
X
X
No Cooling Demand. Wait is Over. Still in
Cut-out Zone.
X
Flashing Fast. Compressor On. Voltage
On (under/over voltage blind time)
X X
X X
Probe #1 Fault. Voltage Bad.
X X
Probe #2 Fault. Voltage Bad.
X X
Mains frequency out of range
KEY:
On/good Flashing (1 sec. interval)
X Off/bad Flashing Fast (.15 sec. interval)
Not relevant Cycling (1 sec. interval)
On Off
°F °C °F °C °F °C
1 -17.2 935.4 33 0.6 340.6 65 18.3 137.4
3 -16.1 875.3 35 1.0 320.9 67 19.4 130.2
5 -15.0 819.5 37 2.8 302.5 69 20.6 123.4
7 -13.9 767.6 39 3.9 285.2 71 21.7 117.0
9 -12.8 719.3 41 5.0 269.0 73 22.8 111.0
11 -11.7 674.3 43 6.1 253.9 75 23.9 105.3
13 -10.6 632.4 45 7.2 239.7 77 25.0 100.0
15 -9.4 593.1 47 8.3 226.3 79 26.1 95.0
17 -8.3 556.7 49 9.4 213.8 81 27.2 90.2
19 -7.2 522.8 51 10.6 202.0 83 28.3 85.7
21 -6.1 491.2 53 11.7 190.9 85 29.4 81.5
23 -5.0 461.7 55 12.8 180.6 87 30.6 77.4
25 -3.9 434.1 57 13.9 170.9 89 31.7 73.7
27 -2.8 408.4 59 15.0 161.7 91 32.8 70.1
29 -1.7 384.3 61 16.1 153.1 93 33.9 66.7
31 -0.6 361.8 63 17.2 145.0 95 35.0 63.5
POSITION
INDICATOR
TO ADJUST COLDER TO ADJUST WARMER
ROTATE
KNOB
CLOCKWISE
TO MAKE
COLDER
COUNTER
CLOCKWISE
TO MAKE
WARMER
Probe 2: Evaporator Probe
(White)
Probe 1: Regulation Probe
(Black)
Red (R)
Yellow (Y) LED Indicators
Green (G)
Neutral
Line
Compressor
PA-NOT USED
RA-EVAP FAN
LED INDICATORS
PROBE RESISTANCE VALUES
TEMPERATURE
CONTROL KNOB