9. STORAGE INSTRUCTIONS
1. Charge battery to full capacity before storage.
2. Store this unit at temperatures between
-
4°F-
+
140°F (
-
20°C-
+
60°C).
3. Never completely discharge the battery.
4. Charge after each use.
5. Charge at least once every month, if not in frequent use, to prevent
over-discharge.
10. TROUBLESHOOTING
Jump Starter
PROBLEM REASON/SOLUTION
The jump starter turns on, but
won’t jump start my vehicle.
Make sure the unit is charged.
Verify the charge level of the jump starter is
at least 50%.
Do not attempt to jump start your vehicle
more than three consecutive times. If
the vehicle still does not start, consult a
qualied service technician.
All four LEDs ash. Low or high temperature. LEDs will stop
ashing when the condition is corrected.
The jump starter will not
recharge.
Make sure the power source is live.
The last LED ashes, then
turns off.
Over-discharge. Recharge the internal
battery.
When cable is connected only
to the battery: Solid Red LED,
(Green LED off); beeps once
per second
The vehicle battery voltage is lower than
10.5V. User can connect to jump starter
and turn key to jump start the vehicle.
When cable is correctly
connected to both battery
and jump starter: Green LED
blinking; Red LED off; no beep.
“Fake” high battery voltage is detected,
but reverse charging protection did not
activate. User can turn key to jump start
the vehicle.
Smart Cable LED and Alarm Behavior
BEHAVIOR REASON
Green LED blinking; Red LED
off; no beep.
Cable is connected to battery only.
Cable is connected to jump starter only.
Green LED solid; Red LED off;
no beep.
Cable is connected correctly to both
battery and jump starter.
Solid Red LED, Green LED off;
beeps once per second
Low voltage protection
Solid Red LED, Green LED off;
beeps twice per second
Reverse polarity protection