3.3 Air Ducting
3.3A Inlet Ducting
Occasionallytheareatobelteredisdifculttoaccessand/
ortheunitcannotbelocatedinthearea.Insuchcases,the
aircanbeductedtotheunit’sinlet.
Around16”diameterexibleductcanbeattachedtothe
unitinlet.Itconnectsbyplacingthewireintheductoverthe
ductcollarlipatonelocationandworkingoveritoverthelip
gradually.Itmayberemovedafteruseforeasiertransport
and storage. Flexible 16” duct is available from Therma-Stor
LLC.(4028357)
3.3B Outlet Ducting
A detachable trapazoid shaped exhaust ring is supplied that
willallow10”roundlay-atplasticducttobeattachedto
thePhoenixGuardianRHEPASystemoutlet.Lay-atplastic
ductingisavailablefromTherma-StorLLC.(4024935)
To attach ducting to the collar, remove the ring from the unit
by pressing release tab at the top of the grill. Put the plastic
duct end through the inside of the ring. Roll the duct end
outwardsothatitover-lapstheoutsideofthering.Clipthe
ring back onto the exhaust grill.
3.3C Negative Air Ducting
ThePhoenixGuardianRHEPASystemcanbeusedtolter
and exhaust air from a space. When exhausting to outside
thespace,thespacewillbeunderaslightnegativepressure.
Thiswillhelppreventairborneparticlesfromleavingthe
space,becausethenegativepressurewilldrawairinthrough
openingsinthespace’sexteriorsurfaces.
CAUTION: Exhausting too much air from a space with open
combustion devices (e.g. furnace, fireplace or water heater)
can cause those devices to backdraft. This can contaminate
the space with potentially fatal gases.
Insuchcases,thePhoenixGuardianRHEPASystemmustbe
usedinoneofthefollowingthreeways:
A. Asalteringunitonly.Exhaustingnoairfromthe
space and thus causing no negative pressure or
backdrafting.
B. Exhaustingaverylimitedamountofairwhichdoesnot
causebackdrafting.IncaseB,theopencombustion
devices must be thoroughly checked to guarantee that
theydonotbackdraftwhilethePhoenixGuardianRHEPA
System is running.
C. DirecttheoutletductfromtheGuardianRHEPASystem
totheroomwiththeopencombustiondevice(s).Thiswill
positivelypressurizetheroomwithHEPAlteredair,thus
preventing backdrafting. As in case B, those combustion
devices must be checked after the GuardianR HEPA
System is running to guarantee that they are not
backdrafting.
3.4 Power/Speed Control
Thepower/speedswitchislocatedonthecontrolpanel.
Whenturnedontoanyspeed,itpowerstheimpellerfan.
Occasionallytheimpellerfanmaynotstartonlowspeed.If
this occurs, rotate the speed control to high speed until the
impellerfanstarts,thenadjustittoalowerspeed.
CAUTION: Do not remove HEPA filter with the unit on.
Removing the top and filters while running will expose the
dangerous rotating impeller fan. Disconnect the appliance
before changing filters.