8. Chimney Fire
In the event of a chimney re
Have the chimney and adjacent structure inspected by
qualied professionals. Hearth & Home Technologies
recommends that NFI or CSIA certied professionals,
or technicians under the direction of certified
professionals, conduct a minimum of an NFPA 211
Level 2 inspection of the chimney.
Replace components of the chimney and replace
as specied by the professionals.
Ensure all joints are properly engaged and the
chimney is properly secured.
WARNING! Risk of Fire! A chimney re can perma-
nently damage your chimney system. Failure to re-
placedamagedcomponentsandmakeproperrepairs
cancauseastructurere.
7. Over-Firing Your Fireplace
WARNING! Risk of Fire! Donotover-re.
Over-firing may ignite creosote or will damage the
replaceandchimney.
Symptoms of over-ring may include one or more of the
following:
chimney connector or replace glowing
roaring, rumbling noises
loud cracking or banging sounds
metal warping
chimney re
Topreventover-ringyourreplace.DONOT:
• useammableliquids
• overloadwithwood
• burntrashorlargeamountsofscraplumber
2. Grate
This replace is designed to be used with the supplied
grate or one approved by HHT.
WARNING! Risk of Fire! Use only the factory-sup-
pliedintegralgrate.
• Keepslogsinplace.
• Allowsproperaircirculationaroundthere.
3. Refractory
The refractory is supplied to contain heat and provide
an attractive interior.
It will break down over time and will need occasional
replacement. Small hairline cracks and discoloration
are normal and do not affect its safety.
WARNING! Risk of Fire! DO NOT burnreplacewith-
out refractory. Use only refractory supplied by Hearth &
HomeTechnologies.
4. Firescreen
The rescreen is provided to control sparks. Keep it
closed when the replace in in use.
WARNING! Risk of Fire or Burns!
• Screenwillnotpreventburningmaterialsfromfalling
out.
• Screenpullsorhandlesmaybehot.
5. Flue Damper
The ue damper must be in the fully opened position
during operation of the replace.
WARNING! Risk of Fire and Asphyxiation! Open
damperpriortooperatingreplace.Acloseddamper
overresthereplaceandspillssmokeandames
into the room.
6. Glass Doors
Glass doors are optional.
WARNING! Risk of Fire! InstallONLYdoorsapproved
byHearth&HomeTechnologies.
WARNING! Risk of Fire and Smoke! Fireplace
equipped with doors should be oeprated only with
doors fully open or doors fully closed. If doors are left
partlyopen, gas and ame maybe drawnout ofthe
freplaceopening.