INSTALLATION
Drilling holes
Drill the holes on top wooden support.
• drill Ø7 hole
• drill Ø45 hole
• cut Ø130 hole
Ø45, for cable
clearance
Ø7, for hood
fastening screws
Ø130, for
470
Front of cabinet
Door / hood fascia
36
210
200
268
Fixing duct spigot
Snap in duct spigot to the rangehood.
Fixing the rangehood
Use 4xM6x40 screws and washers supplied to fasten
the rangehood to the wooden support from upper side.
Fixing flue pipe
Fix a 125mm diameter noncombustible rigid flue pipe.
Fix flue pipe to the exhaust transition duct. Use cable ties
or aluminium tape to secure flue pipe to the duct spigot.
If using a flexible duct, install with the wire helix pulled taut
to minimise pressure loss and noise.
5
flue clearance
Ducted recirculating installation
If ducted recirculating installation is used, carbon filters
are recommended.
AR125WV
Optional carbon filter
An optional carbon filter will diminish cooking odours
in the recirculated air. Depending on the frequency of
use and the type of cooking, the expected life of carbon
filters from 1 to 6 months. Replacement is required. It
is recommended to use carbon filter for recirculating
installation. Using carbon filter will reduce the airflow of
the rangehood.
carbon filter