SERVICE AND ADJUSTMENTS
Replace washers and snap retaining ring securely in
axle groove.
Replace axle cover.
NOTE: To seal tire punctures and prevent flat tires due to
slow leaks, tire sealant may be purchased from your local
parts dealer. Tire sealant also prevents tire dry rot and
corrosion.
WASHERS
RETAINING
AXLE COVER
SQUARE KEY (REAR.A_ _
WHEEL ONLY)
FIG. 28
TO START ENGINE WITH A WEAK BATTERY
See Fig. 29)
WARNING: Lead-acid batteries gen-
erate explosive gases. Keep sparks,
flame and smoking materials away from
batteries. Always wear eye protection
when around batteries.
If your battery is too weak to start the engine, it should be
recharged. (See "BATTERY" in the MAINTENANCE sec-
tion of this manual).
If "jumper cables" are used for emergency starting, follow
this procedure:
IMPORTANT:YOURTRACTORISEQUIPPEDWITHA 12VOLT
SYSTEM.THE OTHERVEHICLE MUST ALSO BE A 12VOLT
SYSTEM.DONOTUSEYOURTRACTORBATTERYTOSTART
OTHERVEHICLES.
TO ATTACH JUMPER CABLES -
Connect one end of the RED cable to the POSITIVE
(+) terminal of each battery(A-B), taking care not to
short against tractor chassis.
Connect one end of the BLACK cable to the NEGATIVE
(-) terminal (C) of fully charged battery.
Connect the other end of the BLACK cable (D) to good
chassis ground, away from fuel tank and battery.
TO REMOVE CABLES, REVERSE ORDER -
BLACK cable first from chassis and then from the fully
charged battery.
RED cable last from both batteries.
WEAK OR DEAD
BATTERY
FULLY CHARGED
BATTERY
FIG. 29
REPLACING BATTERY (See Fig. 30)
&
WARNING: Do not short battery
terminals by allowing a wrench or any
other object to contact both terminals
at the same time. Before connect-
ing battery, remove metal bracelets,
wristwatch bands, rings, etc.
Positive terminal must be connected
first to prevent sparking from acci-
dental grounding.
Lift seat pan to raised position.
Disconnect BLACK battery cable first then RED battery
cable and carefully remove battery from tractor.
Install new battery with terminals in same position as
old battery.
First connect RED battery cable to positive (+)terminal
with hex bolt and keps nut as shown.Tighten securely.
Slide terminal cover over terminal.
Connect BLACK grounding cable to negative (-) ter-
minal with remaining hex bolt and keps nut. Tighten
securely.
DISCARD TERMINAL KEPS NUT HEX BOLT
PROTECTIVE CAPS _ X_ _//
TERMINAL I I
POSITIVE (RED)
CABLE
(BLACK) CABLE
FIG. 30
22