electrical connection
If codes permit and a separate ground wire is used, it is recommended that a
qualiedelectriciandeterminethatthegroundpathisadequate.
Check with a qualied electrician if you are not sure whether the cooktop is
properlygrounded.
DoNotgroundtoagaspipe.
A120-volt,60-Hz,AC-only,15-ampere,fusedelectricalsupplyisrequired.
Atime-delayfuseorcircuitbreakerisrecommended.
Itisrecommendedthataseparatecircuitservingonlythisappliancebeprovided.
The outlet mustbe checkedby a qualied electrician tosee if it is wiredwith correct
polarity.
Thisappliance,wheninstalled,mustbeelectricallygroundedinaccordancewithlocal
codes.
Recommendedgroundmethod
Foryourpersonalsafety,thiscooktopmustbegrounded.
Thiscooktopisequippedwitha3-pronggroundplug.
To minimize possible shock hazard, the cord must be plugged into a mating 3-prong
ground-typeoutlet,groundedinaccordancewiththeNationalElectricalCodeANSI/NFPA
70latesteditionorCanadianElectricalCode(CSA)andlocalcodesandordinances.
Ifamatingoutletisnotavailable,itisthepersonalresponsibilityandobligationofthe
customer to have a properly polarized and grounded, 3-prong outlet installed by a
qualiedelectrician.
Electrical Shock Hazard
Plug into a grounded 3-prong
outlet.
Donotremovegroundprong.
Do not use an adapter.
Failure to follow these
instructions can result in death,
re,orelectricalshock.
Before any operation of
maintenance disconnect the
appliance from the electrical main
supply.
3-prong
ground
plug
Power
supplycord
Groundprong
3-prongpolarized
ground-typeoutlet
Fig. 3.1