4
Water and Ice Dispensers
IMPORTANT:
Allow 3 hours for the refrigerator to cool down and chill water.
The dispensing system will not operate when either the refrigerator
door or freezer drawer is open.
Flush the Water System
Air in the water dispensing system can cause the water dispenser to
drip. After connecting the refrigerator to a water source or replacing the
water filter, flush the water system to force air from the water line.
NOTE: As air is cleared from the system, water may spurt out of the
dispenser.
1. Using a sturdy container, depress and hold the water dispenser
paddle for 5 seconds.
2. Release the dispenser paddle for 5 seconds. Repeat steps 1 and 2
until water begins to flow.
3. Once water begins to flow, continue depressing and releasing the
dispenser pad (5 seconds on, 5 seconds off) until a total of 3 gal.
(12 L) has been dispensed.
Calibrate Measured Fill
Household water pressure may affect the accuracy of the Measured Fill
feature. So, for optimum performance of your water dispenser, you must
first calibrate Measured Fill.
IMPORTANT:
Flush the water system before calibrating Measured Fill.
For best results, calibration should be performed when water is not
being used in the house.
1. Place a sturdy measuring cup (1 cup [237 mL] size) on the
dispenser tray centered in front of the ice/water dispenser paddle.
NOTE: Depending on your model, a measuring cup may be
provided.
2. Press and hold the OPTIONS and LOCK buttons at the
same time for 3 seconds. The words “Back” and “1 Cup”
will appear on the display screen. Also, the Calibrate
Measured Fill icon will illuminate and remain lit while the
Measured Fill feature is being calibrated.
NOTE: You may press ICE/WATER “Back” at any time to exit
calibration mode. The Calibrate Measured Fill icon will disappear.
3. Press and release the ice/water dispenser paddle, as needed, to
dispense water to the 1 cup fill line.
NOTE: If overfilling or spilling occurs, discard the water and press
ICE/WATER “Back” to restart the calibration process.
4. When 1 cup of water has been correctly dispensed into the
measuring cup, press the MEASURED FILL button under the word
“Confirm” to confirm the calibration.
When Measured Fill calibration has been confirmed the icons will
disappear and the display will return to the home screen.