2. PERSONAL SAFETY PRECAUTIONS
2.1 Wear complete eye protection and protective clothing when working near lead-acid batteries. Always
have someone nearby for help.
2.2 Have plenty of fresh water, soap and baking soda nearby for use, in case battery acid contacts your
eyes, skin, or clothing. Wash immediately with soap and water and seek medical attention.
2.3 If battery acid comes in contact with eyes, ush eyes immediately for a minimum 10 minutes and get
medical attention.
2.4 Neutralize any acid spills thoroughly with baking soda before attempting to clean up.
2.5 Remove all personal metal items from your body, such as rings, bracelets, necklaces and watches. A
battery can produce a short circuit current high enough to weld a ring to metal, causing a severe burn.
2.6 Never smoke or allow a spark or ame in the vicinity of the battery or engine.
3. FEATURES
1. Worklight ON/OFF switch
2. Rotary switch for USB and jump starter
3. Built-in work light
4. Battery status indicators
5. Battery status button
6. USB port
7. 12V DC power outlet
8. Battery clamps
9. Air compressor gauge
10. Air compressor ON/OFF switch
11. Internal battery charger port
12. Air compressor hose wrap cleats
13. Air compressor hose
14. Air compressor adapters and storage bag
3
5
4
6
7
8
1
2
9
14
13
10
11
12
4. CHARGING THE INTERNAL BATTERY OF THE JUMP STARTER
IMPORTANT: CHARGE IMMEDIATELY AFTER PURCHASE, AFTER EACH USE AND EVERY 30 DAYS,
TO KEEP THE UNIT’S INTERNAL BATTERY FULLY CHARGED AND PROLONG BATTERY LIFE.
4.1 CHECKING THE LEVEL OF THE INTERNAL BATTERY
Press the Battery Status button on the front of the unit. The LED lights will indicate the current charge
level as follows:
RED – less than 20% of full charge; immediately charge the unit.
YELLOW/ORANGE – 20-80% of full charge.
GREEN – more than 80% of full charge.
4.2 CHARGING THE INTERNAL BATTERY
Charge the unit’s internal battery using an extension cord (not included).
NOTE: Use of an improper extension cord could result in a risk of re and electric shock.
1. To charge, ip the AC connector on the back of the unit DOWN and plug in an 18 AWG or larger
extension cord.
2. Plug the extension cord into a 120VAC electrical wall outlet.
3. While the jump starter is charging, the RED LED will be on. Complete charging may take up to 72 hours.
When the RED LED turns off, the jump starter is ready to use.