Troubleshooting
Try these troubleshooting tips before making a service call. They
may save you time and money.
Dryer Symptom Possible Cause/Solution
Dryer won’t start For dryers equipped with a power cord, make sure the power
cord is plugged all the way into the electrical outlet.
Make sure loading door is closed.
Push timer knob in to start dryer.
Make sure the laundry room fuse(s) isn’t blown or loose, or cir-
cuit breakers aren’t open.
The dryer itself does not have an electrical fuse. An electric
dryer has an electrical circuit with two fuses.
Check if motor overload protector has cycled. Wait 10 minutes
and try again.
Dryer won’t heat Make sure timer is not in COOL DOWN, COOL TUMBLE or EX-
TENDED TUMBLE seings or that Fabric Selector is not set at
NO HEAT.
Electric dryers only – Some homes may have two fuses or cir-
cuit breakers for an electric dryer; both fuses or circuit break-
ers should be checked. Make sure the laundry room fuse(s) isn’t
blown or loose, or that the circuit breakers aren’t open.
The dryer itself does not have an electrical fuse. An electric
dryer has an electrical circuit with two fuses.
Gas dryer only – Make sure equipment and main gas line valve is
turned on.
Check exhaust duct to outside to see if it is kinked, blocked or
needs cleaning.
Check weather hood to make sure flapper moves freely, has not
been pushed in or has not been blocked.
Dryer doesn’t dry clothes satisfactorily Check exhaust duct to outside to see if it is kinked, blocked or
needs cleaning.
Check weather hood to make sure flapper moves freely, has not
been pushed in or has not been blocked.
Automatic cycle – Adjust to MAX, MORE or LESS DRY seing.
Timed cycle - Allow more or less time.
Clean the lint filter.
Make sure the load isn’t too small. Small loads may not tumble
properly or dry evenly.
Check load being dried. Heavy items dried with lightweight
items will not dry as quickly as the rest of the load.
Refer to Sort section for proper sorting information.