TO BE COMPLETED BY THE INSTALLER
Complete and keep for safe reference:
Model
Serial no.
Purchase date
Purchaser
Dealer address
Installer’s name
Installer’s signature
Installation company
Installation date
GENERAL
Specified clearance maintained.
Backguard installed if clearance to combustibles behind unit is less than 6" (152mm).
Unit is level–front to back and side to side.
Griddle (if equiped) and burner pan supports are level and does not rock.
All packaging materials have been removed.
Oven door hinges seated and door opens and closes properly.
Dials turn correctly and freely.
Burners light satisfactorily, both individually and with other burners operating.
Flame adjustments made if required.
FINAL CHECKLIST
GAS
Connection: 1/2 NPT with a minimum 5/8" diameter flex line. Site gas supply is
compatible with cooktop model, and sufficient pressure is available
The pressure regulator which is connected to the manifold is set for 5.0" W.C. for natural
gas or 10.0" W.C. for LP.
anual gas shut-off valve installed in an accessible location.
Unit tested and free of gas leaks.
ELECTRICAL
Receptacle with correctly rated over-current protection is provided for service
cordconnection.
Adequate ground connection.