Maytag MLE24PDAGW0 Commercial Stacked Electric Dryer

INSTALLATION INSTRUCTIONS - Page 5

For MLE24PDAGW0. Also, The document are for others Maytag models: MLE24PD*, MLE24PN*

PDF File Manual, 36 pages, Read Online | Download pdf file

MLE24PDAGW0 photo
Loading ...
Loading ...
Loading ...
Product Dimensions
topdryer
exhaust
\
940 mm
(37")
1
1041 mm
(41 ")
__ 79 mm
_. (31/8")
bottom
Back View dryer
exhaust
343 mm
(131/2")
..... j_
140 mm (51/2 '')
686 mm (27")
door
603 mm
(233/4'')
1
743 mm
(291/4 '')
T
1950 mm
(763/4'')
V
approx. 25 mm
(1")
Side View
This dryer is supplied without an electric cord and plug. It must
be connected by a competent electrician to a single-phase
electricity supply at the voltage shown on the dataplate, using a
suitable fixed wiring installation in accordance with local and
national wiring regulations.
[] A 3-wire cord of minimum conductor size 6 mm 2 cross-
section area should be used.
[] A 45A supply fuse should be used, and a switch having a
contact separation in both poles that provides full
disconnection under over-voltage category Ill conditions must
be incorporated into the fixed wiring in accordance with local
wiring regulations. The dryer should be positioned so that the
disconnection switch is easily accessible to the user.
[] A cord clamp bushing is provided on the dryer, and should be
tightened on completion of wiring. The electrical mains
terminals are located behind the small rear access panel
(terminal block cover), and connections should be made in
accordance with the terminal markings. Remember to replace
the terminal access panel (terminal block cover).
NOTE: In accordance with the European EMC Directive
(2004/108/EC), the maximum electricity supply system
impedance to which the electric dryer should be connected
is declared to be 0.01 + J 0.007 Ohms.
Electric Shock Hazard
Electric earthing is required on this dryer.
Do not earth to a gas pipe.
Do not have a fuse in the neutral or earthing circuit.
Check with a qualified electrician to be sure the dryer is
properly earthed.
Failure to follow these instructions could result in
death, fire, or serious injury.
If codes permit and an additional earth bond wire is used, it is
recommended that a qualified electrician determine that the earth
bond path is adequate.
Recommended Earthing Method
[] It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformance with all local codes and ordinances.
5