This mode allows the HydroTap to Go into Energy Saving mode.
To activate the sleep mode:
1. Press [MENU] button for main
menu.
2. Press [Setting] button.
3. Press [Energy Modes] button.
4. Press [Sleep Modes] button then in
the next screen, use the up and down
arrows to select one of the 4 options, as
shown in the table below.
Energy Modes
In Sleep Mode the unit will Go to “Sleep” after a 2hr period of inactivity.
The Chilled water will be ON or OFF.
When the period of inactivity passes, the home screen status window will
show “Sleep Mode”.
Sleep Mode
Light
Level
Time
Delay
State Boiler Chiller
2 Hours-> OFF N/A 2 Hr OFF OFF OFF
Lux Sensor-> OFF Dark N/A OFF OFF OFF
Lux or 2 Hr-> OFF Dark 2 Hr OFF OFF OFF
Disable N/A N/A ON ON ON
Lux (Light) Sensor Calibration: (Not for Elite tap)
It is recommended to recalibrate the Lux (Light) Sensor after selecting any of
the 4 Lux sensor options from the sleep mode menu. Before commencing,
ensure there are ‘Normal to Dim’ (Not Dark) operating light conditions.
Note:
Any attempt, during OFF mode, to dispense water, will bring the unit
out of sleep mode. The unit will return to sleep mode after 2 hours of non
use. Please allow sufficient time for the water to reach the set temperature
after disabling the sleep mode.