3.2 Specialty Fan Wiring - Thermostat (AFG PRO-3.0)
1. For this installation, you will need a 2 wire Romex, and a thermostat.
2. Open up the thermostat that is connected to the fan. Remove the power cord. Bring your 2 wire Romex
from the power source into the thermostat.
3. With a wire nut, tie the white common wires together.
4. Tie the black wire from the fan to one of the black wires from the thermostat. Either black wire from the
thermostat will work.
5. Tie the black wire from the power source to the remaining black wire from the thermostat.
6. Using the ground screw in the thermostat, ground your power source and the green wire from the fan.
7. Mount the thermostat to one of the joists near the attic fan.
WIRING THE THERMOSTAT REMOTELY:
1. For this installation, you will need a 2 wire Romex, junction box, and a thermostat.
2. Open up the thermostat that is connected to the fan. Remove the power cord. Remove the bracket
mounting the thermostat to the flex tubing and remove the thermostat.
3. Mount the junction box to the flex tubing with the included bracket and mount the junction box. Bring
your 2 wire romex from the power source into the junction box.
4. Mount the thermostat in the best location for thermostat readings. Run a 2 wire Romex from the junction
box to the thermostat. Tape the white wire on each side of the 2 wire Romex to indicate that it is a switch
leg.
Figure 3.2A: Thermostat Wiring
Ground the fan and power to the thermostat
using the green ground screw
Specialty Series Fan
Power Source
14-2 Wire
14-2 Wire
60°
Thermostat
FAN ON
TEMPERATURE
90°
120°
®
ADJUSTABLE
TEMPERATURE THERMOSTAT
CAUTION
Automatically started device - to reduce the
risk of injury disconnect from power supply
before servicing. For residential use only. See
instructions for wiring diagram.
60°
ADVANCED ATTIC GABLE FANS
®
Ground the fan and power to the thermostat
using the green ground screw
Specialty Series Fan
Power Source
14-2 Wire
14-2 Wire
60°
Thermostat
FAN ON
TEMPERATURE
90°
120°
®
ADJUSTABLE
TEMPERATURE THERMOSTAT
CAUTION
Automatically started device - to reduce the
risk of injury disconnect from power supply
before servicing. For residential use only. See
instructions for wiring diagram.
60°
ADVANCED ATTIC GABLE FANS
®
Loading ...