User Manual Canarm IFM1612BK Clip Flush Mount

Documents for Canarm IFM1612BK

The following documents are available:
User Manual Specification

User Manual

For IFM1612BK.

1. Install nipple to mounting bracket and lock in place with hex nut.
Nipple must be adjusted to clear the hole in the center of the Fixture.
2. Attach mounting bracket to wiring box with wiring box screws
(not included). Start ground screw into mounting bracket.
3. Firmly attach the fixture ground wire (bare copper) to the
mounting bracket with the ground screw (by wrapping around the
ground screw) and then connect it to the house supply ground wire
with a wire nut. Connect the black wire (or wire with marking)
from the fixture to the black wire in the electrical box and connect the
white wire from the fixture to the white wire in the electrical box.
4. Once connections of wires are completed, carefully tuck wires and
wire nuts into the outlet box making sure no bare wire (on the black
and white) is visible at the wire nuts. Align the center hole in the
fixture with the nipple in the mounting bracket. Secure the fixture in
place with a cap nut.
5. Install proper bulb type and wattage (not included).
6. Install the glass shade by pulling the decorative clip that is spring
loaded outward. Position the edge of the glass into the other two clips
Cap Nut
Mounting Bracket
Hex Nut
Nipple
Spring
Loaded
Clip
Glass
Ground Screw
Outlet Box
Screws
(not included)
FM-2
08/10
INSTALLATION: Note: Your fixture may have either one or two sockets depending on the model.
CEILING LIGHT
Imported By: CANARM LTD., 2157 Parkedale Ave., Brockville, Ontario, K6V 5V6,Tel: (613) 342-5424, Fax: (613) 342-8437
L
I
G
H
T
I
N
G
&
F
A
N
S
E
C
L
A
I
R
A
G
E
S
&
V
E
N
T
I
L
A
T
E
U
R
S
QUESTIONS OR CONCERNS CONTACT CANARM AT:
1-800-265-1833 (English) / 1-800-567-2513 (French)
Monday through Friday 8:00 AM to 5:00 PM E.S.T.
SAFETY PRECAUTIONS:
1. TURN OFF ELECTRICAL POWER BEFORE STARTING INSTALLATION OF LIGHT FIXTURE.
DO NOT REMOVE INSULATION FROM FIXTURE.
2. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE
BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
3. CAUTION – RISK OF FIRE. CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT
CONDUCTOR.
4. FIRMLY ATTACH THE FIXTURE GROUND WIRE (BARE COPPER) TO THE MOUNTING BRACKET WITH THE
GROUND SCREW (BY WRAPPING AROUND THE GROUND SCREW) AND THEN CONNECT IT TO THE
HOUSE SUPPLY GROUND WIRE WITH A WIRE NUT.
NOTE: Product May Not Look Exactly As Shown In Figures.
!
“INSTRUCTIONS PERTAINING TO RISK OF FIRE OR INJURY TO PERSONS”
“READ ALL INSTRUCTIONS”
“IMPORTANT SAFETY
INSTRUCTIONS
“SAVE THESE INSTRUCTIONS”
TOOLS AND MATERIALS REQUIRED:
Phillips
Screwdriver
Wire Cutters
Wiring supplies
as required by
electrical code
Pliers Wrench
Blade
Screwdriver
White
Black
House supply
Ground wire
Fixture
Ground wire