56 - INSTALLATION 914779930/A
Appliance overall dimensions
1
Minimum distance from side walls or other
flammable material.
2
Minimum cabinet width (=A)
Appliance dimensions
Levelling the appliance
The appliance must be level on the floor in order
to ensure greater stability:
Screw or unscrew the feet at the bottom until
the appliance is stable and level on the
floor.
Assembling the upstand
The upstand must always be positioned and
secured correctly on the appliance.
1. Loosen the 6 screws (A) on the back of the
hob (2 for each side and 2 at the centre)
using a screwdriver.
2. Place the upstand on the hob.
3. Align the slots of the upstand (B) with the
screws (A).
If a hood is installed above the
appliance, refer to the hood instructions
manual to make sure the correct
clearance is left.
A 1103 mm
B 600 mm
C
1
min. 150 mm
D 898 - 920 mm
H 750 mm
I 450 mm
L
2
1103 mm
Position of electrical connection
LL
HH
II
CC CC
AA
BB
DD
888888
11031103
636,5636,5
5555
The upstand provided is an integral part
of the product. It must be fastened to the
appliance prior to installation.
AA
BB
Loading ...