KBU328ASD KingsBottle 53 Inch Stainless Steel Beverage Center

User Manual - Page 9

For KBU328ASD.

PDF File Manual, 16 pages, Read Online | Download pdf file

KBU328ASD photo
Loading ...
Loading ...
Loading ...
CODE
DESCRIPTION
MIN
MAX
UOM
DEFAULT
PS
password
0
200
-
22
"
PROBE PARAMETERS
"
"
"
/2
probe measurement stability
1
15
-
10
/4
select probe/input displayed ( /4=1, display air probe; /4=2, display evaporator
probe; /4=3, display the status of LED figure ON or OFF)
1
3
-
1
/5
select °C/°F (0= °C; 1= °F )
0
1
-
1
/6
disable decimal point
0
1
-
1
/C1
probe 1 offset
-12,7
12,7
(°C/°F) / 10
1.6
/C2
probe 2 offset
-12,7
12,7
(°C/°F) / 10
0
"
CONTROL PARAMETERS
"
"
"
St
user set point
r1
r2
°C/°F
41.0
rd
STANDARD differential
0,0
19,0
°C/°F
3.2
r1
minimum set point allowed to the user
-50
r2
°C/°F
41.0
r2
maximum set point allowed
r1
150
°C/°F
64.4
"
COMPRESSOR PARAMETERS
"
"
"
c0
Start delay when COMPRESSOR ON is required by the Regulation
1
200
Min
6
c1
delay between 2 consecutive starts
0
100
Min
0
c2
minimum compressor OFF time
0
100
Min
6
c3
minimum compressor ON time
0
100
Min
0
c4
compressor ON time with duty setting
0
100
Min
0
"
DEFROST PARAMETERS
"
"
"
d0
Type of defrost
0
2
-
1
dI
Start defrost condition : interval time
0
199
Hours
6
ds
defrost interval time calculating:
ds=0, calculate time of compressor operating
ds=1, calculate time after power ON
0
1
-
1
dt
End defrost condition : evaporator temperature threshold
-50
127
°C/°F
59.0
dP
End defrost condition : max time defrost duration
1
199
Min
20
d4
if defrost when switching the instrument on ( 0=no ; 1=yes )
0
1
-
0
dH
defrost delay on power-up ( when d4=1)
0
199
Min
0
d6
temperature displayed “frozen” during defrost ( when d6=0 “dF” is displayed);
Freeze regulation probe temperature before defrost start (when d6=1)
0
1
-
1
dd
dripping time ( stop compressor after defrost )
0
15
Min
0
d8
LOW temperature alarm bypass time after defrost
0
15
Hours
0
d9
defrost priority over compressor protectors ( if d9=1 c2, c3, c4 are bypassed )
0
1
-
0
d/
Evaporator probe reading (read only)
-
-
°C/°F
-
d10
Start defrost condition : evaporator temperature threshold
-50
127
°C/°F
-7.6
d11
Enabling defrost condition : regulation probe threshold.
-50
127
°C/°F
86
d12
No-downward tendency defrost, Start condition : time with
Comp.continuously ON and Reg.Probe doesn’t decrease
A10
199
(200=disabled)
Min
180
"
ALARM PARAMETERS
"
"
"
A0
alarm temperature differential
-20
20
°C/°F
0
AL
absolute/relative temperature for low temperature alarm
-50
150
°C/°F
-30.2
AH
absolute/relative temperature for high temperature alarm
-50
150
°C/°F
82.4
Ad
temperature alarm delay
0
199
Min
120
A10
Open Door Alarm delay
0
10
Min
0
"
EVAPORATOR FAN PARAMETERS
"
"
"
F0
Start delay when FAN ON is required by the Regulation
1
100
sec
1
Fd0
Fan STANDARD Duty Cycle : ON time
1
100
Min
1
FdF
Fan STANDARD Duty Cycle : OFF time
1
100
Min
1
"
OTHER PARAMETERS
"
"
"
H0
supervisor serial address
0
207
-
1
H4
disable buzzer ( 1 = disable )
0
1
0
H5
ID code (read-only)
-199
199
-
1
TABLE OF PARAMETERS
!
www.kingsbottle.com" 9
Loading ...
Loading ...
Loading ...