Maytag MDE17MNAGW0 commercial dryer

User Manual - Page 5

For MDE17MNAGW0.

PDF File Manual, 32 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Product Dimensions 686 mm (27") dryer
_----686 mm (27")
m--m I
1
!
ELECTRIC "_q_----_
I 343 mm
(131/2'')
BACK VIEW
349 mm
,, 102mm(4")
_l dia.
i,/
743 mm (291A'')
673 mm (261/2'')
I .... I
I
I
I
SIDE VIEW
889mm
(35")
L_
25 mm
(1")
........ i
892 mm
(351/s'')
73 mm
(27/8'')
:=m=_m
This dryer is supplied without an electric cord and plug. It
must be connected by a competent electrician to a single-phase
electricity supply at the voltage shown on the dataptate, using
a suitable fixed wiring installation in accordance with local and
national wiring regulations.
[] A 3-wire circular cord of minimum conductor size 2.5 mm2
cross-section area should be used.
[] A 30A supply fuse should be used, and a switch having
a contact separation in both poles that provides full
disconnection under over-voltage category Ill conditions must
be incorporated into the fixed wiring in accordance with local
wiring regulations. The dryer should be positioned so that the
disconnection switch is easily accessible to the user.
[] A cord clamp bush is provided on the dryer, and should
be tightened on completion of wiring. The electrical mains
terminals are located behind the small rear access panel
(terminal block cover), and connections should be made
in accordance with the terminal markings. Remember to
replace the terminal access panel (terminal block cover).
NOTE: In accordance with the European EMC Directive
(2004/108/EC), the maximum electricity supply system
impedance to which the electric dryer should be connected
is declared to be 0.302 Ohm + j0.189 Ohm.
Electric Shock Hazard
Electric earthing is required on this dryer.
Do not earth to a gas pipe.
Do not have a fuse in the neutral or earthing circuit.
Check with a qualified electrician to be sure the dryer is
properly earthed.
Failure to follow these instructions could result in
death, fire, or serious injury.
If codes permit and an additional earth bond wire is used, it is
recommended that a qualified electrician determine that the earth
bond path is adequate.
AUSTRALIA ONLY
For Australia, each single electric dryer is fitted with a cord
and plug, with conductors of 2.5 mm2 cross sectional area,
and should be plugged into a suitable electrical socket at the
voltage shown on the dataptate. Do not use extension lead
assemblies on commercial installations. If the supply cord is
damaged, it must be replaced with a specially terminated cord
by an authorized service agent or a similarly qualified person in
order to avoid a hazard. Each electric dryer for other countries
is supplied without an electric cord and plug.
Recommended Earthing Method
[] It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformance with all local codes and ordinances.
5