Tosot TW24HQ2C2D Single Zone Mini Split System with 27300 BTU Cooling Capacity

Owner's Manual - Page 33

For TW24HQ2C2D. Also, The document are for others Tosot models: TW12HQ3C2AI(WIFI), TW12HQ3C2DI(WIFI)

PDF File Manual, 44 pages, Read Online | Download pdf file

TW24HQ2C2D photo
Loading ...
Loading ...
Loading ...
1. There should be no obstruction near air inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the
power socket.
4. Select a location which is out of reach for children.
5. The location should be able to withstand the weight of indoor unit and won't
increase noise and vibration.
6. The appliance must be installed 2.5m above oor.
7. Don't install the indoor unit right above the electric appliance.
8. Please try your best to keep way from uorescent lamp.
Tools for installation
Selection of installation location
1 Level meter 2 Screw driver 3 Impact drill
4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter 9 Leakage detector
10 Vacuum pump 11 Pressure meter 12 Universal meter
13 Inner hexagon spanner 14 Measuring tape
Note:
Please contact the local agent for installation.
Don't use unqualied power cord.
Basic requirement
Indoor unit
Installing the unit in the following places maycause malfunction. If it is unavoidable,
please consult the local dealer:
1. The place with strong heat sources,
vapors, ammable or explosive gas
, or
volatile objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical
equipment).
3. The place near coast area.
4.
The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. Do not use the unit in the immediate surroundings of a laundry a bath a
shower or a swimming pool.
Loading ...
Loading ...
Loading ...