Air connection systems
20
EXTRACTION VERSION
The maximum length of the duct covers is 850 mm. Bend the two
appendages for fastening the lower duct cover by 90°; see the figure
on page 12. Position the 2 brackets for the upper duct cover at the
upper limit indicated; see figures on pages 11 and 12. Mark the two
holes on the wall for fastening the brackets. Drill the holes and
fasten the brackets using the expansion plugs provided. Connect the
fume extraction duct (inside diameter Ø 150 mm) to the motor
outlet. The duct is not supplied. The diameter of the extraction duct
must not be less than Ø 120 mm. Carefully place the two duct
covers on the hood. Move the upper duct cover slightly to allow the
lower duct cover to be fastened to the hood using the 2 screws. Lift
the upper duct cover to the specified upper limit. Secure the upper
duct cover to the brackets using 2 screws, see figure on page 13.
CAUTION: remove the two odour filters from the hood.
EN