15
Display “E1” or
“E2”.
The air temperature sensor has failed. Call for service.
The alarm
sounds and
the
temperature
display
flashes.
Has the appliance door been open for
longer than 60 seconds? If not, then the
temperature has risen higher or fallen
lower than the temperature that has been
set. This could be due to:
The appliance door being opened too
often.
The ventilation opening being covered
or too dusty.
A lengthy interruption to the power
supply.
A large amount of food or beverage has
been added to the unit.
If yes, close the door.
Do not open the door more often than
necessary.
Clear the obstructions and clean the
dust.
Leave the appliance to work for a
while until the set temperature has
been reached.
The icon “--” is
lit and flashing
in the
temperature
display.
The display temperature is out of range.
Only temperatures within the range
0~99°F/-9~37°C for SPR315OS /
SPR625OS and the range -49~99°F/
-45~37°C for SCFF51OS can be
displayed. If the temperature is not
within this range, the icon “--will be
displayed instead. This is normal.